MeterIdentification
- class st.zigbee.zcl.clusters.MeterIdentification
- ID: number
0x0B01 the ID of this cluster
- NAME: str
“MeterIdentification” the name of this cluster
- attributes: st.zigbee.zcl.clusters.MeterIdentificationServerAttributes or st.zigbee.zcl.clusters.MeterIdentificationClientAttributes
- commands: st.zigbee.zcl.clusters.MeterIdentificationServerCommands or st.zigbee.zcl.clusters.MeterIdentificationClientCommands
- types: st.zigbee.zcl.clusters.MeterIdentificationTypes
MeterIdentification Attributes
- class st.zigbee.zcl.clusters.MeterIdentification.CompanyName
- ID: number
0x0000 the ID of this attribute
- NAME: str
“CompanyName” the name of this attribute
- data_type: st.zigbee.data_types.CharString
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.CharString
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.CharString
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a CharString object of this attribute with any additional features provided for the attribute
This is also usable with the CompanyName(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a CharString- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.CharString
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.MeterIdentification.MeterTypeID
- ID: number
0x0001 the ID of this attribute
- NAME: str
“MeterTypeID” the name of this attribute
- data_type: st.zigbee.data_types.Uint16
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint16 object of this attribute with any additional features provided for the attribute
This is also usable with the MeterTypeID(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint16- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint16
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.MeterIdentification.DataQualityID
- ID: number
0x0004 the ID of this attribute
- NAME: str
“DataQualityID” the name of this attribute
- data_type: st.zigbee.data_types.Uint16
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint16 object of this attribute with any additional features provided for the attribute
This is also usable with the DataQualityID(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint16- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint16
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.MeterIdentification.CustomerName
- ID: number
0x0005 the ID of this attribute
- NAME: str
“CustomerName” the name of this attribute
- data_type: st.zigbee.data_types.CharString
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.CharString
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.CharString
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a CharString object of this attribute with any additional features provided for the attribute
This is also usable with the CustomerName(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a CharString- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.CharString
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.CharString
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.MeterIdentification.Model
- ID: number
0x0006 the ID of this attribute
- NAME: str
“Model” the name of this attribute
- data_type: st.zigbee.data_types.OctetString
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.OctetString
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.OctetString
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a OctetString object of this attribute with any additional features provided for the attribute
This is also usable with the Model(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a OctetString- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.OctetString
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.MeterIdentification.PartNumber
- ID: number
0x0007 the ID of this attribute
- NAME: str
“PartNumber” the name of this attribute
- data_type: st.zigbee.data_types.OctetString
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.OctetString
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.OctetString
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a OctetString object of this attribute with any additional features provided for the attribute
This is also usable with the PartNumber(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a OctetString- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.OctetString
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.MeterIdentification.ProductRevision
- ID: number
0x0008 the ID of this attribute
- NAME: str
“ProductRevision” the name of this attribute
- data_type: st.zigbee.data_types.OctetString
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.OctetString
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.OctetString
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a OctetString object of this attribute with any additional features provided for the attribute
This is also usable with the ProductRevision(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a OctetString- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.OctetString
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.MeterIdentification.SoftwareRevision
- ID: number
0x000A the ID of this attribute
- NAME: str
“SoftwareRevision” the name of this attribute
- data_type: st.zigbee.data_types.OctetString
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.OctetString
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.OctetString
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a OctetString object of this attribute with any additional features provided for the attribute
This is also usable with the SoftwareRevision(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a OctetString- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.OctetString
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.MeterIdentification.UtilityName
- ID: number
0x000B the ID of this attribute
- NAME: str
“UtilityName” the name of this attribute
- data_type: st.zigbee.data_types.CharString
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.CharString
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.CharString
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a CharString object of this attribute with any additional features provided for the attribute
This is also usable with the UtilityName(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a CharString- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.CharString
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.MeterIdentification.POD
- ID: number
0x000C the ID of this attribute
- NAME: str
“POD” the name of this attribute
- data_type: st.zigbee.data_types.CharString
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.CharString
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.CharString
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a CharString object of this attribute with any additional features provided for the attribute
This is also usable with the POD(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a CharString- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.CharString
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.MeterIdentification.AvailablePower
- ID: number
0x000D the ID of this attribute
- NAME: str
“AvailablePower” the name of this attribute
- data_type: st.zigbee.data_types.Int24
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Int24
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Int24
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Int24 object of this attribute with any additional features provided for the attribute
This is also usable with the AvailablePower(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Int24- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Int24
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.MeterIdentification.PowerThreshold
- ID: number
0x000E the ID of this attribute
- NAME: str
“PowerThreshold” the name of this attribute
- data_type: st.zigbee.data_types.Int24
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Int24
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Int24
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Int24 object of this attribute with any additional features provided for the attribute
This is also usable with the PowerThreshold(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Int24- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Int24
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –