PressureMeasurement

class st.zigbee.zcl.clusters.PressureMeasurement
ID: number

0x0403 the ID of this cluster

NAME: str

“PressureMeasurement” the name of this cluster

attributes: st.zigbee.zcl.clusters.PressureMeasurementServerAttributes or st.zigbee.zcl.clusters.PressureMeasurementClientAttributes
commands: st.zigbee.zcl.clusters.PressureMeasurementServerCommands or st.zigbee.zcl.clusters.PressureMeasurementClientCommands
types: st.zigbee.zcl.clusters.PressureMeasurementTypes

PressureMeasurement Attributes

class st.zigbee.zcl.clusters.PressureMeasurement.MeasuredValue
ID: number

0x0000 the ID of this attribute

NAME: str

“MeasuredValue” the name of this attribute

data_type: st.zigbee.data_types.Int16

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Int16 object of this attribute with any additional features provided for the attribute

This is also usable with the MeasuredValue(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Int16

Return type

st.zigbee.data_types.Int16

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Int16) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PressureMeasurement.MinMeasuredValue
ID: number

0x0001 the ID of this attribute

NAME: str

“MinMeasuredValue” the name of this attribute

data_type: st.zigbee.data_types.Int16

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Int16 object of this attribute with any additional features provided for the attribute

This is also usable with the MinMeasuredValue(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Int16

Return type

st.zigbee.data_types.Int16

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Int16) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PressureMeasurement.MaxMeasuredValue
ID: number

0x0002 the ID of this attribute

NAME: str

“MaxMeasuredValue” the name of this attribute

data_type: st.zigbee.data_types.Int16

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Int16 object of this attribute with any additional features provided for the attribute

This is also usable with the MaxMeasuredValue(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Int16

Return type

st.zigbee.data_types.Int16

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Int16) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PressureMeasurement.Tolerance
ID: number

0x0003 the ID of this attribute

NAME: str

“Tolerance” the name of this attribute

data_type: st.zigbee.data_types.Uint16

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint16 object of this attribute with any additional features provided for the attribute

This is also usable with the Tolerance(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint16

Return type

st.zigbee.data_types.Uint16

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint16) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PressureMeasurement.ScaledValue
ID: number

0x0010 the ID of this attribute

NAME: str

“ScaledValue” the name of this attribute

data_type: st.zigbee.data_types.Int16

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Int16 object of this attribute with any additional features provided for the attribute

This is also usable with the ScaledValue(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Int16

Return type

st.zigbee.data_types.Int16

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Int16) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PressureMeasurement.MinScaledValue
ID: number

0x0011 the ID of this attribute

NAME: str

“MinScaledValue” the name of this attribute

data_type: st.zigbee.data_types.Int16

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Int16 object of this attribute with any additional features provided for the attribute

This is also usable with the MinScaledValue(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Int16

Return type

st.zigbee.data_types.Int16

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Int16) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PressureMeasurement.MaxScaledValue
ID: number

0x0012 the ID of this attribute

NAME: str

“MaxScaledValue” the name of this attribute

data_type: st.zigbee.data_types.Int16

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Int16 object of this attribute with any additional features provided for the attribute

This is also usable with the MaxScaledValue(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Int16

Return type

st.zigbee.data_types.Int16

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Int16) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PressureMeasurement.ScaledTolerance
ID: number

0x0013 the ID of this attribute

NAME: str

“ScaledTolerance” the name of this attribute

data_type: st.zigbee.data_types.Uint16

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint16 object of this attribute with any additional features provided for the attribute

This is also usable with the ScaledTolerance(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint16

Return type

st.zigbee.data_types.Uint16

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint16) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PressureMeasurement.Scale
ID: number

0x0014 the ID of this attribute

NAME: str

“Scale” the name of this attribute

data_type: st.zigbee.data_types.Int8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Int8 object of this attribute with any additional features provided for the attribute

This is also usable with the Scale(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Int8

Return type

st.zigbee.data_types.Int8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Int8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

set_parent_cluster(cluster)
Parameters

cluster (any) –

PressureMeasurement Commands