RelativeHumidity
- class st.zigbee.zcl.clusters.RelativeHumidity
- ID: number
0x0405 the ID of this cluster
- NAME: str
“RelativeHumidity” the name of this cluster
- attributes: st.zigbee.zcl.clusters.RelativeHumidityServerAttributes or st.zigbee.zcl.clusters.RelativeHumidityClientAttributes
- commands: st.zigbee.zcl.clusters.RelativeHumidityServerCommands or st.zigbee.zcl.clusters.RelativeHumidityClientCommands
- types: st.zigbee.zcl.clusters.RelativeHumidityTypes
RelativeHumidity Attributes
- class st.zigbee.zcl.clusters.RelativeHumidity.MeasuredValue
- ID: number
0x0000 the ID of this attribute
- NAME: str
“MeasuredValue” the name of this attribute
- data_type: st.zigbee.data_types.Uint16
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint16 object of this attribute with any additional features provided for the attribute
This is also usable with the MeasuredValue(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint16- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint16
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.RelativeHumidity.MinMeasuredValue
- ID: number
0x0001 the ID of this attribute
- NAME: str
“MinMeasuredValue” the name of this attribute
- data_type: st.zigbee.data_types.Uint16
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint16 object of this attribute with any additional features provided for the attribute
This is also usable with the MinMeasuredValue(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint16- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint16
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.RelativeHumidity.MaxMeasuredValue
- ID: number
0x0002 the ID of this attribute
- NAME: str
“MaxMeasuredValue” the name of this attribute
- data_type: st.zigbee.data_types.Uint16
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint16 object of this attribute with any additional features provided for the attribute
This is also usable with the MaxMeasuredValue(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint16- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint16
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.RelativeHumidity.Tolerance
- ID: number
0x0003 the ID of this attribute
- NAME: str
“Tolerance” the name of this attribute
- data_type: st.zigbee.data_types.Uint16
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint16 object of this attribute with any additional features provided for the attribute
This is also usable with the Tolerance(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint16- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint16
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –