Rate Tbl Report¶
- class st.zwave.CommandClass.RateTblMonitor.RateTblReport¶
Dynamically versioned RATE_TBL_REPORT
Supported versions: 1; unique base versions: 1
- cmd_class: number¶
0x49
- cmd_id: number¶
0x04
- version: number¶
1
- args: st.zwave.CommandClass.RateTblMonitor.RateTblReportV1Args¶
- construct(module, args)¶
Construct a RATE_TBL_REPORT object at the module instance serialization version.
- Parameters:
module (
st.zwave.CommandClass.RateTblMonitor) – command class module instanceargs (
st.zwave.CommandClass.RateTblMonitor.RateTblReportV1Args) – command-specific arguments
- Return type:
- class st.zwave.CommandClass.RateTblMonitor.RateTblReportV1: st.zwave.Command¶
v1 RATE_TBL_REPORT
- cmd_class: number¶
0x49
- cmd_id: number¶
0x04
- version: number¶
1
- args: st.zwave.CommandClass.RateTblMonitor.RateTblReportV1Args¶
command-specific arguments
- init(module, args)¶
Initialize a v1 RATE_TBL_REPORT object.
- Parameters:
module (
st.zwave.CommandClass.RateTblMonitor) – command class module instanceargs (
st.zwave.CommandClass.RateTblMonitor.RateTblReportV1Args) – command-specific arguments
- serialize()¶
Serialize v1 RATE_TBL_REPORT arguments.
- Returns:
serialized payload
- Return type:
str
- deserialize()¶
Deserialize a v1 RATE_TBL_REPORT payload.
- Returns:
deserialized arguments
- Return type:
- class st.zwave.CommandClass.RateTblMonitor.RateTblReportV1Args¶
- rate_parameter_set_id: integer¶
[0,255]
- rate_type: integer¶
[0,3]
- rate_character: str¶
- start_hour_local_time: integer¶
[0,255]
- start_minute_local_time: integer¶
[0,255]
- duration_minute: integer¶
[0,65535]
- consumption_scale: integer¶
[0,31]
- consumption_precision: integer¶
[0,7]
- min_consumption_value: number¶
[-2147483648,2147483647]
- max_consumption_value: number¶
[-2147483648,2147483647]
- max_demand_scale: integer¶
[0,31]
- max_demand_precision: integer¶
[0,7]
- max_demand_value: number¶
[-2147483648,2147483647]
- dcp_rate_id: integer¶
[0,255]