Supported Report
- class st.zwave.CommandClass.ThermostatFanMode.SupportedReport
Dynamically versioned THERMOSTAT_FAN_MODE_SUPPORTED_REPORT
Supported versions: 1,2,3,4,5; unique base versions: 1,2,3,4
- cmd_class: number
0x44
- cmd_id: number
0x05
- version: number
1,2,3,4
- args: st.zwave.CommandClass.ThermostatFanMode.SupportedReportV1Args or st.zwave.CommandClass.ThermostatFanMode.SupportedReportV2Args or st.zwave.CommandClass.ThermostatFanMode.SupportedReportV3Args or st.zwave.CommandClass.ThermostatFanMode.SupportedReportV4Args
- construct(module, args)
Construct a THERMOSTAT_FAN_MODE_SUPPORTED_REPORT object at the module instance serialization version.
- Parameters
module (
st.zwave.CommandClass.ThermostatFanMode
) – command class module instanceargs (
st.zwave.CommandClass.ThermostatFanMode.SupportedReportV1Args or st.zwave.CommandClass.ThermostatFanMode.SupportedReportV2Args or st.zwave.CommandClass.ThermostatFanMode.SupportedReportV3Args or st.zwave.CommandClass.ThermostatFanMode.SupportedReportV4Args
) – command-specific arguments
- Return type
- class st.zwave.CommandClass.ThermostatFanMode.SupportedReportV1: st.zwave.Command
v1 THERMOSTAT_FAN_MODE_SUPPORTED_REPORT
- cmd_class: number
0x44
- cmd_id: number
0x05
- version: number
1
- args: st.zwave.CommandClass.ThermostatFanMode.SupportedReportV1Args
command-specific arguments
- init(module, args)
Initialize a v1 THERMOSTAT_FAN_MODE_SUPPORTED_REPORT object.
- Parameters
module (
st.zwave.CommandClass.ThermostatFanMode
) – command class module instanceargs (
st.zwave.CommandClass.ThermostatFanMode.SupportedReportV1Args
) – command-specific arguments
- serialize()
Serialize v1 THERMOSTAT_FAN_MODE_SUPPORTED_REPORT arguments.
- Returns
serialized payload
- Return type
str
- deserialize()
Deserialize a v1 THERMOSTAT_FAN_MODE_SUPPORTED_REPORT payload.
- Returns
deserialized arguments
- Return type
st.zwave.CommandClass.ThermostatFanMode.SupportedReportV1Args
- class st.zwave.CommandClass.ThermostatFanMode.SupportedReportV1Args
- auto: boolean
- on: boolean
- auto_high: boolean
- on_high: boolean
- class st.zwave.CommandClass.ThermostatFanMode.SupportedReportV2: st.zwave.Command
v2 THERMOSTAT_FAN_MODE_SUPPORTED_REPORT
- cmd_class: number
0x44
- cmd_id: number
0x05
- version: number
2
- args: st.zwave.CommandClass.ThermostatFanMode.SupportedReportV2Args
command-specific arguments
- init(module, args)
Initialize a v2 THERMOSTAT_FAN_MODE_SUPPORTED_REPORT object.
- Parameters
module (
st.zwave.CommandClass.ThermostatFanMode
) – command class module instanceargs (
st.zwave.CommandClass.ThermostatFanMode.SupportedReportV2Args
) – command-specific arguments
- serialize()
Serialize v2 THERMOSTAT_FAN_MODE_SUPPORTED_REPORT arguments.
- Returns
serialized payload
- Return type
str
- deserialize()
Deserialize a v2 THERMOSTAT_FAN_MODE_SUPPORTED_REPORT payload.
- Returns
deserialized arguments
- Return type
st.zwave.CommandClass.ThermostatFanMode.SupportedReportV2Args
- class st.zwave.CommandClass.ThermostatFanMode.SupportedReportV2Args
- auto: boolean
- low: boolean
- auto_high: boolean
- high: boolean
- auto_medium: boolean
- medium: boolean
- class st.zwave.CommandClass.ThermostatFanMode.SupportedReportV3: st.zwave.Command
v3 THERMOSTAT_FAN_MODE_SUPPORTED_REPORT
- cmd_class: number
0x44
- cmd_id: number
0x05
- version: number
3
- args: st.zwave.CommandClass.ThermostatFanMode.SupportedReportV3Args
command-specific arguments
- init(module, args)
Initialize a v3 THERMOSTAT_FAN_MODE_SUPPORTED_REPORT object.
- Parameters
module (
st.zwave.CommandClass.ThermostatFanMode
) – command class module instanceargs (
st.zwave.CommandClass.ThermostatFanMode.SupportedReportV3Args
) – command-specific arguments
- serialize()
Serialize v3 THERMOSTAT_FAN_MODE_SUPPORTED_REPORT arguments.
- Returns
serialized payload
- Return type
str
- deserialize()
Deserialize a v3 THERMOSTAT_FAN_MODE_SUPPORTED_REPORT payload.
- Returns
deserialized arguments
- Return type
st.zwave.CommandClass.ThermostatFanMode.SupportedReportV3Args
- class st.zwave.CommandClass.ThermostatFanMode.SupportedReportV3Args
- auto: boolean
- low: boolean
- auto_high: boolean
- high: boolean
- auto_medium: boolean
- medium: boolean
- circulation: boolean
- humidity_circulation: boolean
- class st.zwave.CommandClass.ThermostatFanMode.SupportedReportV4: st.zwave.Command
v4 and forward-compatible v5 THERMOSTAT_FAN_MODE_SUPPORTED_REPORT
- cmd_class: number
0x44
- cmd_id: number
0x05
- version: number
4
- args: st.zwave.CommandClass.ThermostatFanMode.SupportedReportV4Args
command-specific arguments
- init(module, args)
Initialize a v4 and forward-compatible v5 THERMOSTAT_FAN_MODE_SUPPORTED_REPORT object.
- Parameters
module (
st.zwave.CommandClass.ThermostatFanMode
) – command class module instanceargs (
st.zwave.CommandClass.ThermostatFanMode.SupportedReportV4Args
) – command-specific arguments
- serialize()
Serialize v4 or forward-compatible v5 THERMOSTAT_FAN_MODE_SUPPORTED_REPORT arguments.
- Returns
serialized payload
- Return type
str
- deserialize()
Deserialize a v4 or forward-compatible v5 THERMOSTAT_FAN_MODE_SUPPORTED_REPORT payload.
- Returns
deserialized arguments
- Return type
st.zwave.CommandClass.ThermostatFanMode.SupportedReportV4Args