AnalogOutput

class st.zigbee.zcl.clusters.AnalogOutput
ID: number

0x000D the ID of this cluster

NAME: str

“AnalogOutput” the name of this cluster

attributes: st.zigbee.zcl.clusters.AnalogOutputServerAttributes or st.zigbee.zcl.clusters.AnalogOutputClientAttributes
commands: st.zigbee.zcl.clusters.AnalogOutputServerCommands or st.zigbee.zcl.clusters.AnalogOutputClientCommands
types: st.zigbee.zcl.clusters.AnalogOutputTypes

AnalogOutput Attributes

class st.zigbee.zcl.clusters.AnalogOutput.Description
ID: number

0x001C the ID of this attribute

NAME: str

“Description” the name of this attribute

data_type: st.zigbee.data_types.CharString

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a CharString object of this attribute with any additional features provided for the attribute

This is also usable with the Description(…) syntax

Parameters

vararg (vararg) – the values needed to construct a CharString

Return type

st.zigbee.data_types.CharString

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.CharString) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.AnalogOutput.MaxPresentValue
ID: number

0x0041 the ID of this attribute

NAME: str

“MaxPresentValue” the name of this attribute

data_type: st.zigbee.data_types.SinglePrecisionFloat

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a SinglePrecisionFloat object of this attribute with any additional features provided for the attribute

This is also usable with the MaxPresentValue(…) syntax

Parameters

vararg (vararg) – the values needed to construct a SinglePrecisionFloat

Return type

st.zigbee.data_types.SinglePrecisionFloat

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.SinglePrecisionFloat) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.AnalogOutput.MinPresentValue
ID: number

0x0045 the ID of this attribute

NAME: str

“MinPresentValue” the name of this attribute

data_type: st.zigbee.data_types.SinglePrecisionFloat

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a SinglePrecisionFloat object of this attribute with any additional features provided for the attribute

This is also usable with the MinPresentValue(…) syntax

Parameters

vararg (vararg) – the values needed to construct a SinglePrecisionFloat

Return type

st.zigbee.data_types.SinglePrecisionFloat

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.SinglePrecisionFloat) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.AnalogOutput.OutOfService
ID: number

0x0051 the ID of this attribute

NAME: str

“OutOfService” the name of this attribute

data_type: st.zigbee.data_types.Boolean

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Boolean object of this attribute with any additional features provided for the attribute

This is also usable with the OutOfService(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Boolean

Return type

st.zigbee.data_types.Boolean

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.AnalogOutput.PresentValue
ID: number

0x0055 the ID of this attribute

NAME: str

“PresentValue” the name of this attribute

data_type: st.zigbee.data_types.SinglePrecisionFloat

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a SinglePrecisionFloat object of this attribute with any additional features provided for the attribute

This is also usable with the PresentValue(…) syntax

Parameters

vararg (vararg) – the values needed to construct a SinglePrecisionFloat

Return type

st.zigbee.data_types.SinglePrecisionFloat

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.SinglePrecisionFloat) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.AnalogOutput.Reliability
ID: number

0x0067 the ID of this attribute

NAME: str

“Reliability” the name of this attribute

data_type: st.zigbee.data_types.Enum8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Enum8 object of this attribute with any additional features provided for the attribute

This is also usable with the Reliability(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Enum8

Return type

st.zigbee.data_types.Enum8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.AnalogOutput.RelinquishDefault
ID: number

0x0068 the ID of this attribute

NAME: str

“RelinquishDefault” the name of this attribute

data_type: st.zigbee.data_types.SinglePrecisionFloat

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a SinglePrecisionFloat object of this attribute with any additional features provided for the attribute

This is also usable with the RelinquishDefault(…) syntax

Parameters

vararg (vararg) – the values needed to construct a SinglePrecisionFloat

Return type

st.zigbee.data_types.SinglePrecisionFloat

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.SinglePrecisionFloat) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.AnalogOutput.Resolution
ID: number

0x006A the ID of this attribute

NAME: str

“Resolution” the name of this attribute

data_type: st.zigbee.data_types.SinglePrecisionFloat

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a SinglePrecisionFloat object of this attribute with any additional features provided for the attribute

This is also usable with the Resolution(…) syntax

Parameters

vararg (vararg) – the values needed to construct a SinglePrecisionFloat

Return type

st.zigbee.data_types.SinglePrecisionFloat

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.SinglePrecisionFloat) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.AnalogOutput.StatusFlags
ID: number

0x006F the ID of this attribute

NAME: str

“StatusFlags” the name of this attribute

data_type: st.zigbee.data_types.Bitmap8

the data type of this attribute

augment_type(base_type_obj)

Add additional functionality to the base type object

Parameters

base_type_obj (st.zigbee.data_types.Bitmap8) – the base data type object to add functionality to

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Bitmap8 object of this attribute with any additional features provided for the attribute

This is also usable with the StatusFlags(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Bitmap8

Return type

st.zigbee.data_types.Bitmap8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.AnalogOutput.EngineeringUnits
ID: number

0x0075 the ID of this attribute

NAME: str

“EngineeringUnits” the name of this attribute

data_type: st.zigbee.data_types.Enum16

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Enum16 object of this attribute with any additional features provided for the attribute

This is also usable with the EngineeringUnits(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Enum16

Return type

st.zigbee.data_types.Enum16

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.AnalogOutput.ApplicationType
ID: number

0x0100 the ID of this attribute

NAME: str

“ApplicationType” the name of this attribute

data_type: st.zigbee.data_types.Uint32

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint32 object of this attribute with any additional features provided for the attribute

This is also usable with the ApplicationType(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint32

Return type

st.zigbee.data_types.Uint32

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint32) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

set_parent_cluster(cluster)
Parameters

cluster (any) –

AnalogOutput Commands