DehumidificationControl
- class st.zigbee.zcl.clusters.DehumidificationControl
- ID: number
0x0203 the ID of this cluster
- NAME: str
“DehumidificationControl” the name of this cluster
- attributes: st.zigbee.zcl.clusters.DehumidificationControlServerAttributes or st.zigbee.zcl.clusters.DehumidificationControlClientAttributes
- commands: st.zigbee.zcl.clusters.DehumidificationControlServerCommands or st.zigbee.zcl.clusters.DehumidificationControlClientCommands
- types: st.zigbee.zcl.clusters.DehumidificationControlTypes
DehumidificationControl Attributes
- class st.zigbee.zcl.clusters.DehumidificationControl.RelativeHumidity
- ID: number
0x0000 the ID of this attribute
- NAME: str
“RelativeHumidity” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the RelativeHumidity(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.DehumidificationControl.DehumidificationCooling
- ID: number
0x0001 the ID of this attribute
- NAME: str
“DehumidificationCooling” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the DehumidificationCooling(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.DehumidificationControl.RHDehumidificationSetpoint
- ID: number
0x0010 the ID of this attribute
- NAME: str
“RHDehumidificationSetpoint” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the RHDehumidificationSetpoint(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.DehumidificationControl.RelativeHumidityMode
- ID: number
0x0011 the ID of this attribute
- NAME: str
“RelativeHumidityMode” the name of this attribute
- data_type: st.zigbee.data_types.Enum8
the data type of this attribute
- MEASURED_LOCALLY: number
0
- UPDATED_OVER_THE_NETWORK: number
1
- augment_type(base_type_obj)
Add additional functionality to the base type object
- Parameters
base_type_obj (
st.zigbee.data_types.Enum8
) – the base data type object to add functionality to
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Enum8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Enum8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Enum8 object of this attribute with any additional features provided for the attribute
This is also usable with the RelativeHumidityMode(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Enum8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attribute
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Enum8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.DehumidificationControl.DehumidificationLockout
- ID: number
0x0012 the ID of this attribute
- NAME: str
“DehumidificationLockout” the name of this attribute
- data_type: st.zigbee.data_types.Enum8
the data type of this attribute
- DEHUMIDIFICATION_NOT_ALLOWED: number
0
- DEHUMIDIFICATION_ALLOWED: number
1
- augment_type(base_type_obj)
Add additional functionality to the base type object
- Parameters
base_type_obj (
st.zigbee.data_types.Enum8
) – the base data type object to add functionality to
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Enum8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Enum8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Enum8 object of this attribute with any additional features provided for the attribute
This is also usable with the DehumidificationLockout(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Enum8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attribute
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Enum8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.DehumidificationControl.DehumidificationHysteresis
- ID: number
0x0013 the ID of this attribute
- NAME: str
“DehumidificationHysteresis” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the DehumidificationHysteresis(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.DehumidificationControl.DehumidificationMaxCool
- ID: number
0x0014 the ID of this attribute
- NAME: str
“DehumidificationMaxCool” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the DehumidificationMaxCool(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.DehumidificationControl.RelativeHumidityDisplay
- ID: number
0x0015 the ID of this attribute
- NAME: str
“RelativeHumidityDisplay” the name of this attribute
- data_type: st.zigbee.data_types.Enum8
the data type of this attribute
- NOT_DISPLAYED: number
0
- DISPLAYED: number
1
- augment_type(base_type_obj)
Add additional functionality to the base type object
- Parameters
base_type_obj (
st.zigbee.data_types.Enum8
) – the base data type object to add functionality to
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Enum8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Enum8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Enum8 object of this attribute with any additional features provided for the attribute
This is also usable with the RelativeHumidityDisplay(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Enum8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attribute
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Enum8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –