DehumidificationControl

class st.zigbee.zcl.clusters.DehumidificationControl
ID: number

0x0203 the ID of this cluster

NAME: str

“DehumidificationControl” the name of this cluster

attributes: st.zigbee.zcl.clusters.DehumidificationControlServerAttributes or st.zigbee.zcl.clusters.DehumidificationControlClientAttributes
commands: st.zigbee.zcl.clusters.DehumidificationControlServerCommands or st.zigbee.zcl.clusters.DehumidificationControlClientCommands
types: st.zigbee.zcl.clusters.DehumidificationControlTypes

DehumidificationControl Attributes

class st.zigbee.zcl.clusters.DehumidificationControl.RelativeHumidity
ID: number

0x0000 the ID of this attribute

NAME: str

“RelativeHumidity” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the RelativeHumidity(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.DehumidificationControl.DehumidificationCooling
ID: number

0x0001 the ID of this attribute

NAME: str

“DehumidificationCooling” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the DehumidificationCooling(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.DehumidificationControl.RHDehumidificationSetpoint
ID: number

0x0010 the ID of this attribute

NAME: str

“RHDehumidificationSetpoint” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the RHDehumidificationSetpoint(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.DehumidificationControl.RelativeHumidityMode
ID: number

0x0011 the ID of this attribute

NAME: str

“RelativeHumidityMode” the name of this attribute

data_type: st.zigbee.data_types.Enum8

the data type of this attribute

MEASURED_LOCALLY: number

0

UPDATED_OVER_THE_NETWORK: number

1

augment_type(base_type_obj)

Add additional functionality to the base type object

Parameters

base_type_obj (st.zigbee.data_types.Enum8) – the base data type object to add functionality to

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Enum8 object of this attribute with any additional features provided for the attribute

This is also usable with the RelativeHumidityMode(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Enum8

Return type

st.zigbee.data_types.Enum8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.DehumidificationControl.DehumidificationLockout
ID: number

0x0012 the ID of this attribute

NAME: str

“DehumidificationLockout” the name of this attribute

data_type: st.zigbee.data_types.Enum8

the data type of this attribute

DEHUMIDIFICATION_NOT_ALLOWED: number

0

DEHUMIDIFICATION_ALLOWED: number

1

augment_type(base_type_obj)

Add additional functionality to the base type object

Parameters

base_type_obj (st.zigbee.data_types.Enum8) – the base data type object to add functionality to

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Enum8 object of this attribute with any additional features provided for the attribute

This is also usable with the DehumidificationLockout(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Enum8

Return type

st.zigbee.data_types.Enum8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.DehumidificationControl.DehumidificationHysteresis
ID: number

0x0013 the ID of this attribute

NAME: str

“DehumidificationHysteresis” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the DehumidificationHysteresis(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.DehumidificationControl.DehumidificationMaxCool
ID: number

0x0014 the ID of this attribute

NAME: str

“DehumidificationMaxCool” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the DehumidificationMaxCool(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.DehumidificationControl.RelativeHumidityDisplay
ID: number

0x0015 the ID of this attribute

NAME: str

“RelativeHumidityDisplay” the name of this attribute

data_type: st.zigbee.data_types.Enum8

the data type of this attribute

NOT_DISPLAYED: number

0

DISPLAYED: number

1

augment_type(base_type_obj)

Add additional functionality to the base type object

Parameters

base_type_obj (st.zigbee.data_types.Enum8) – the base data type object to add functionality to

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Enum8 object of this attribute with any additional features provided for the attribute

This is also usable with the RelativeHumidityDisplay(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Enum8

Return type

st.zigbee.data_types.Enum8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

DehumidificationControl Commands