PowerConfiguration
- class st.zigbee.zcl.clusters.PowerConfiguration
- ID: number
0x0001 the ID of this cluster
- NAME: str
“PowerConfiguration” the name of this cluster
- attributes: st.zigbee.zcl.clusters.PowerConfigurationServerAttributes or st.zigbee.zcl.clusters.PowerConfigurationClientAttributes
- commands: st.zigbee.zcl.clusters.PowerConfigurationServerCommands or st.zigbee.zcl.clusters.PowerConfigurationClientCommands
- types: st.zigbee.zcl.clusters.PowerConfigurationTypes
PowerConfiguration Attributes
- class st.zigbee.zcl.clusters.PowerConfiguration.MainsVoltage
- ID: number
0x0000 the ID of this attribute
- NAME: str
“MainsVoltage” the name of this attribute
- data_type: st.zigbee.data_types.Uint16
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint16 object of this attribute with any additional features provided for the attribute
This is also usable with the MainsVoltage(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint16- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint16
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.MainsFrequency
- ID: number
0x0001 the ID of this attribute
- NAME: str
“MainsFrequency” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the MainsFrequency(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.MainsAlarmMask
- ID: number
0x0010 the ID of this attribute
- NAME: str
“MainsAlarmMask” the name of this attribute
- data_type: st.zigbee.data_types.Bitmap8
the data type of this attribute
- MAINS_VOLTAGE_TOO_LOW: number
1
- MAINS_VOLTAGE_TOO_HIGH: number
2
- MAINS_POWER_SUPPLY_LOST: number
4
- is_mains_voltage_too_low_set()
- Returns
True if the value of MAINS_VOLTAGE_TOO_LOW is non-zero
- Return type
boolean
- set_mains_voltage_too_low()
Set the value of the bit in the MAINS_VOLTAGE_TOO_LOW field to 1
- unset_mains_voltage_too_low()
Set the value of the bits in the MAINS_VOLTAGE_TOO_LOW field to 0
- is_mains_voltage_too_high_set()
- Returns
True if the value of MAINS_VOLTAGE_TOO_HIGH is non-zero
- Return type
boolean
- set_mains_voltage_too_high()
Set the value of the bit in the MAINS_VOLTAGE_TOO_HIGH field to 1
- unset_mains_voltage_too_high()
Set the value of the bits in the MAINS_VOLTAGE_TOO_HIGH field to 0
- is_mains_power_supply_lost_set()
- Returns
True if the value of MAINS_POWER_SUPPLY_LOST is non-zero
- Return type
boolean
- set_mains_power_supply_lost()
Set the value of the bit in the MAINS_POWER_SUPPLY_LOST field to 1
- unset_mains_power_supply_lost()
Set the value of the bits in the MAINS_POWER_SUPPLY_LOST field to 0
- augment_type(base_type_obj)
Add additional functionality to the base type object
- Parameters
base_type_obj (
st.zigbee.data_types.Bitmap8
) – the base data type object to add functionality to
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Bitmap8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Bitmap8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Bitmap8 object of this attribute with any additional features provided for the attribute
This is also usable with the MainsAlarmMask(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Bitmap8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attribute
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Bitmap8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.MainsVoltageMinThreshold
- ID: number
0x0011 the ID of this attribute
- NAME: str
“MainsVoltageMinThreshold” the name of this attribute
- data_type: st.zigbee.data_types.Uint16
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint16 object of this attribute with any additional features provided for the attribute
This is also usable with the MainsVoltageMinThreshold(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint16- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint16
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint16
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.MainsVoltageMaxThreshold
- ID: number
0x0012 the ID of this attribute
- NAME: str
“MainsVoltageMaxThreshold” the name of this attribute
- data_type: st.zigbee.data_types.Uint16
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint16 object of this attribute with any additional features provided for the attribute
This is also usable with the MainsVoltageMaxThreshold(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint16- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint16
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint16
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.MainsVoltageDwellTripPoint
- ID: number
0x0013 the ID of this attribute
- NAME: str
“MainsVoltageDwellTripPoint” the name of this attribute
- data_type: st.zigbee.data_types.Uint16
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint16 object of this attribute with any additional features provided for the attribute
This is also usable with the MainsVoltageDwellTripPoint(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint16- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint16
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint16
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.BatteryVoltage
- ID: number
0x0020 the ID of this attribute
- NAME: str
“BatteryVoltage” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the BatteryVoltage(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.BatteryPercentageRemaining
- ID: number
0x0021 the ID of this attribute
- NAME: str
“BatteryPercentageRemaining” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the BatteryPercentageRemaining(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.BatteryManufacturer
- ID: number
0x0030 the ID of this attribute
- NAME: str
“BatteryManufacturer” the name of this attribute
- data_type: st.zigbee.data_types.CharString
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.CharString
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.CharString
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a CharString object of this attribute with any additional features provided for the attribute
This is also usable with the BatteryManufacturer(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a CharString- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.CharString
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.CharString
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.BatterySize
- ID: number
0x0031 the ID of this attribute
- NAME: str
“BatterySize” the name of this attribute
- data_type: st.zigbee.zcl.clusters.PowerConfiguration.types.BatterySize
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.zcl.clusters.PowerConfiguration.types.BatterySize
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.zcl.clusters.PowerConfiguration.types.BatterySize
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a BatterySizeType object of this attribute with any additional features provided for the attribute
This is also usable with the BatterySize(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a BatterySizeType- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.zcl.clusters.PowerConfiguration.types.BatterySize
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.zcl.clusters.PowerConfiguration.types.BatterySize
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.BatteryAHrRating
- ID: number
0x0032 the ID of this attribute
- NAME: str
“BatteryAHrRating” the name of this attribute
- data_type: st.zigbee.data_types.Uint16
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint16 object of this attribute with any additional features provided for the attribute
This is also usable with the BatteryAHrRating(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint16- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint16
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint16
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.BatteryQuantity
- ID: number
0x0033 the ID of this attribute
- NAME: str
“BatteryQuantity” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the BatteryQuantity(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.BatteryRatedVoltage
- ID: number
0x0034 the ID of this attribute
- NAME: str
“BatteryRatedVoltage” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the BatteryRatedVoltage(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.BatteryAlarmMask
- ID: number
0x0035 the ID of this attribute
- NAME: str
“BatteryAlarmMask” the name of this attribute
- data_type: st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmMask
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmMask
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmMask
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a BatteryAlarmMaskType object of this attribute with any additional features provided for the attribute
This is also usable with the BatteryAlarmMask(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a BatteryAlarmMaskType- Return type
st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmMask
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmMask
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmMask
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.BatteryVoltageMinThreshold
- ID: number
0x0036 the ID of this attribute
- NAME: str
“BatteryVoltageMinThreshold” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the BatteryVoltageMinThreshold(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.BatteryVoltageThreshold1
- ID: number
0x0037 the ID of this attribute
- NAME: str
“BatteryVoltageThreshold1” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the BatteryVoltageThreshold1(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.BatteryVoltageThreshold2
- ID: number
0x0038 the ID of this attribute
- NAME: str
“BatteryVoltageThreshold2” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the BatteryVoltageThreshold2(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.BatteryVoltageThreshold3
- ID: number
0x0039 the ID of this attribute
- NAME: str
“BatteryVoltageThreshold3” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the BatteryVoltageThreshold3(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.BatteryPercentageMinThreshold
- ID: number
0x003A the ID of this attribute
- NAME: str
“BatteryPercentageMinThreshold” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the BatteryPercentageMinThreshold(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.BatteryPercentageThreshold1
- ID: number
0x003B the ID of this attribute
- NAME: str
“BatteryPercentageThreshold1” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the BatteryPercentageThreshold1(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.BatteryPercentageThreshold2
- ID: number
0x003C the ID of this attribute
- NAME: str
“BatteryPercentageThreshold2” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the BatteryPercentageThreshold2(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.BatteryPercentageThreshold3
- ID: number
0x003D the ID of this attribute
- NAME: str
“BatteryPercentageThreshold3” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the BatteryPercentageThreshold3(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.BatteryAlarmState
- ID: number
0x003E the ID of this attribute
- NAME: str
“BatteryAlarmState” the name of this attribute
- data_type: st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmState
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmState
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmState
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a BatteryAlarmStateType object of this attribute with any additional features provided for the attribute
This is also usable with the BatteryAlarmState(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a BatteryAlarmStateType- Return type
st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmState
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmState
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.Battery2Voltage
- ID: number
0x0040 the ID of this attribute
- NAME: str
“Battery2Voltage” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the Battery2Voltage(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.Battery2PercentageRemaining
- ID: number
0x0041 the ID of this attribute
- NAME: str
“Battery2PercentageRemaining” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the Battery2PercentageRemaining(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.Battery2Manufacturer
- ID: number
0x0050 the ID of this attribute
- NAME: str
“Battery2Manufacturer” the name of this attribute
- data_type: st.zigbee.data_types.CharString
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.CharString
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.CharString
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a CharString object of this attribute with any additional features provided for the attribute
This is also usable with the Battery2Manufacturer(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a CharString- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.CharString
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.CharString
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.Battery2Size
- ID: number
0x0051 the ID of this attribute
- NAME: str
“Battery2Size” the name of this attribute
- data_type: st.zigbee.zcl.clusters.PowerConfiguration.types.BatterySize
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.zcl.clusters.PowerConfiguration.types.BatterySize
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.zcl.clusters.PowerConfiguration.types.BatterySize
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a BatterySizeType object of this attribute with any additional features provided for the attribute
This is also usable with the Battery2Size(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a BatterySizeType- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.zcl.clusters.PowerConfiguration.types.BatterySize
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.zcl.clusters.PowerConfiguration.types.BatterySize
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.Battery2AHrRating
- ID: number
0x0052 the ID of this attribute
- NAME: str
“Battery2AHrRating” the name of this attribute
- data_type: st.zigbee.data_types.Uint16
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint16 object of this attribute with any additional features provided for the attribute
This is also usable with the Battery2AHrRating(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint16- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint16
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint16
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.Battery2Quantity
- ID: number
0x0053 the ID of this attribute
- NAME: str
“Battery2Quantity” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the Battery2Quantity(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.Battery2RatedVoltage
- ID: number
0x0054 the ID of this attribute
- NAME: str
“Battery2RatedVoltage” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the Battery2RatedVoltage(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.Battery2AlarmMask
- ID: number
0x0055 the ID of this attribute
- NAME: str
“Battery2AlarmMask” the name of this attribute
- data_type: st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmMask
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmMask
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmMask
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a BatteryAlarmMaskType object of this attribute with any additional features provided for the attribute
This is also usable with the Battery2AlarmMask(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a BatteryAlarmMaskType- Return type
st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmMask
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmMask
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmMask
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.Battery2VoltageMinThreshold
- ID: number
0x0056 the ID of this attribute
- NAME: str
“Battery2VoltageMinThreshold” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the Battery2VoltageMinThreshold(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.Battery2VoltageThreshold1
- ID: number
0x0057 the ID of this attribute
- NAME: str
“Battery2VoltageThreshold1” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the Battery2VoltageThreshold1(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.Battery2VoltageThreshold2
- ID: number
0x0058 the ID of this attribute
- NAME: str
“Battery2VoltageThreshold2” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the Battery2VoltageThreshold2(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.Battery2VoltageThreshold3
- ID: number
0x0059 the ID of this attribute
- NAME: str
“Battery2VoltageThreshold3” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the Battery2VoltageThreshold3(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.Battery2PercentageMinThreshold
- ID: number
0x005A the ID of this attribute
- NAME: str
“Battery2PercentageMinThreshold” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the Battery2PercentageMinThreshold(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.Battery2PercentageThreshold1
- ID: number
0x005B the ID of this attribute
- NAME: str
“Battery2PercentageThreshold1” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the Battery2PercentageThreshold1(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.Battery2PercentageThreshold2
- ID: number
0x005C the ID of this attribute
- NAME: str
“Battery2PercentageThreshold2” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the Battery2PercentageThreshold2(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.Battery2PercentageThreshold3
- ID: number
0x005D the ID of this attribute
- NAME: str
“Battery2PercentageThreshold3” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the Battery2PercentageThreshold3(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.Battery2AlarmState
- ID: number
0x005E the ID of this attribute
- NAME: str
“Battery2AlarmState” the name of this attribute
- data_type: st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmState
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmState
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmState
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a BatteryAlarmStateType object of this attribute with any additional features provided for the attribute
This is also usable with the Battery2AlarmState(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a BatteryAlarmStateType- Return type
st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmState
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmState
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.Battery3Voltage
- ID: number
0x0060 the ID of this attribute
- NAME: str
“Battery3Voltage” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the Battery3Voltage(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.Battery3PercentageRemaining
- ID: number
0x0061 the ID of this attribute
- NAME: str
“Battery3PercentageRemaining” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the Battery3PercentageRemaining(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.Battery3Manufacturer
- ID: number
0x0070 the ID of this attribute
- NAME: str
“Battery3Manufacturer” the name of this attribute
- data_type: st.zigbee.data_types.CharString
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.CharString
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.CharString
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a CharString object of this attribute with any additional features provided for the attribute
This is also usable with the Battery3Manufacturer(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a CharString- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.CharString
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.CharString
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.Battery3Size
- ID: number
0x0071 the ID of this attribute
- NAME: str
“Battery3Size” the name of this attribute
- data_type: st.zigbee.zcl.clusters.PowerConfiguration.types.BatterySize
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.zcl.clusters.PowerConfiguration.types.BatterySize
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.zcl.clusters.PowerConfiguration.types.BatterySize
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a BatterySizeType object of this attribute with any additional features provided for the attribute
This is also usable with the Battery3Size(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a BatterySizeType- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.zcl.clusters.PowerConfiguration.types.BatterySize
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.zcl.clusters.PowerConfiguration.types.BatterySize
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.Battery3AHrRating
- ID: number
0x0072 the ID of this attribute
- NAME: str
“Battery3AHrRating” the name of this attribute
- data_type: st.zigbee.data_types.Uint16
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint16 object of this attribute with any additional features provided for the attribute
This is also usable with the Battery3AHrRating(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint16- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint16
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint16
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.Battery3Quantity
- ID: number
0x0073 the ID of this attribute
- NAME: str
“Battery3Quantity” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the Battery3Quantity(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.Battery3RatedVoltage
- ID: number
0x0074 the ID of this attribute
- NAME: str
“Battery3RatedVoltage” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the Battery3RatedVoltage(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.Battery3AlarmMask
- ID: number
0x0075 the ID of this attribute
- NAME: str
“Battery3AlarmMask” the name of this attribute
- data_type: st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmMask
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmMask
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmMask
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a BatteryAlarmMaskType object of this attribute with any additional features provided for the attribute
This is also usable with the Battery3AlarmMask(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a BatteryAlarmMaskType- Return type
st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmMask
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmMask
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmMask
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.Battery3VoltageMinThreshold
- ID: number
0x0076 the ID of this attribute
- NAME: str
“Battery3VoltageMinThreshold” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the Battery3VoltageMinThreshold(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.Battery3VoltageThreshold1
- ID: number
0x0077 the ID of this attribute
- NAME: str
“Battery3VoltageThreshold1” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the Battery3VoltageThreshold1(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.Battery3VoltageThreshold2
- ID: number
0x0078 the ID of this attribute
- NAME: str
“Battery3VoltageThreshold2” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the Battery3VoltageThreshold2(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.Battery3VoltageThreshold3
- ID: number
0x0079 the ID of this attribute
- NAME: str
“Battery3VoltageThreshold3” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the Battery3VoltageThreshold3(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.Battery3PercentageMinThreshold
- ID: number
0x007A the ID of this attribute
- NAME: str
“Battery3PercentageMinThreshold” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the Battery3PercentageMinThreshold(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.Battery3PercentageThreshold1
- ID: number
0x007B the ID of this attribute
- NAME: str
“Battery3PercentageThreshold1” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the Battery3PercentageThreshold1(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.Battery3PercentageThreshold2
- ID: number
0x007C the ID of this attribute
- NAME: str
“Battery3PercentageThreshold2” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the Battery3PercentageThreshold2(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.Battery3PercentageThreshold3
- ID: number
0x007D the ID of this attribute
- NAME: str
“Battery3PercentageThreshold3” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the Battery3PercentageThreshold3(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint8
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.PowerConfiguration.Battery3AlarmState
- ID: number
0x007E the ID of this attribute
- NAME: str
“Battery3AlarmState” the name of this attribute
- data_type: st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmState
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmState
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmState
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a BatteryAlarmStateType object of this attribute with any additional features provided for the attribute
This is also usable with the Battery3AlarmState(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a BatteryAlarmStateType- Return type
st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmState
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmState
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
PowerConfiguration Commands
PowerConfiguration Types
- class st.zigbee.zcl.clusters.PowerConfiguration.types.BatterySize: st.zigbee.data_types.Enum8
- byte_length: number
1
- NO_BATTERY: number
0
- BUILT_IN: number
1
- OTHER: number
2
- AA: number
3
- AAA: number
4
- C: number
5
- D: number
6
- CR2: number
7
- CR123A: number
8
- UNKNOWN: number
255
- class st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmMask: st.zigbee.data_types.Bitmap8
- byte_length: number
1
- BATTERY_VOLTAGE_TOO_LOW: number
1
- BATTERY_ALARM1: number
2
- BATTERY_ALARM2: number
4
- BATTERY_ALARM3: number
8
- is_battery_voltage_too_low_set()
- Returns
True if the value of BATTERY_VOLTAGE_TOO_LOW is non-zero
- Return type
boolean
- set_battery_voltage_too_low()
Set the value of the bit in the BATTERY_VOLTAGE_TOO_LOW field to 1
- unset_battery_voltage_too_low()
Set the value of the bits in the BATTERY_VOLTAGE_TOO_LOW field to 0
- is_battery_alarm1_set()
- Returns
True if the value of BATTERY_ALARM1 is non-zero
- Return type
boolean
- set_battery_alarm1()
Set the value of the bit in the BATTERY_ALARM1 field to 1
- unset_battery_alarm1()
Set the value of the bits in the BATTERY_ALARM1 field to 0
- is_battery_alarm2_set()
- Returns
True if the value of BATTERY_ALARM2 is non-zero
- Return type
boolean
- set_battery_alarm2()
Set the value of the bit in the BATTERY_ALARM2 field to 1
- unset_battery_alarm2()
Set the value of the bits in the BATTERY_ALARM2 field to 0
- is_battery_alarm3_set()
- Returns
True if the value of BATTERY_ALARM3 is non-zero
- Return type
boolean
- set_battery_alarm3()
Set the value of the bit in the BATTERY_ALARM3 field to 1
- unset_battery_alarm3()
Set the value of the bits in the BATTERY_ALARM3 field to 0
- class st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmState: st.zigbee.data_types.Bitmap32
- byte_length: number
4
- BATTERY1MIN_THRESHOLD: number
1
- BATTERY1THRESHOLD1: number
2
- BATTERY1THRESHOLD2: number
4
- BATTERY1THRESHOLD3: number
8
- BATTERY2MIN_THRESHOLD: number
1024
- BATTERY2THRESHOLD1: number
2048
- BATTERY2THRESHOLD2: number
4096
- BATTERY2THRESHOLD3: number
8192
- BATTERY3MIN_THRESHOLD: number
1048576
- BATTERY3THRESHOLD1: number
2097152
- BATTERY3THRESHOLD2: number
4194304
- BATTERY3THRESHOLD3: number
8388608
- MAINS_POWER_SUPPLY_LOST: number
1073741824
- is_battery1min_threshold_set()
- Returns
True if the value of BATTERY1MIN_THRESHOLD is non-zero
- Return type
boolean
- set_battery1min_threshold()
Set the value of the bit in the BATTERY1MIN_THRESHOLD field to 1
- unset_battery1min_threshold()
Set the value of the bits in the BATTERY1MIN_THRESHOLD field to 0
- is_battery1threshold1_set()
- Returns
True if the value of BATTERY1THRESHOLD1 is non-zero
- Return type
boolean
- set_battery1threshold1()
Set the value of the bit in the BATTERY1THRESHOLD1 field to 1
- unset_battery1threshold1()
Set the value of the bits in the BATTERY1THRESHOLD1 field to 0
- is_battery1threshold2_set()
- Returns
True if the value of BATTERY1THRESHOLD2 is non-zero
- Return type
boolean
- set_battery1threshold2()
Set the value of the bit in the BATTERY1THRESHOLD2 field to 1
- unset_battery1threshold2()
Set the value of the bits in the BATTERY1THRESHOLD2 field to 0
- is_battery1threshold3_set()
- Returns
True if the value of BATTERY1THRESHOLD3 is non-zero
- Return type
boolean
- set_battery1threshold3()
Set the value of the bit in the BATTERY1THRESHOLD3 field to 1
- unset_battery1threshold3()
Set the value of the bits in the BATTERY1THRESHOLD3 field to 0
- is_battery2min_threshold_set()
- Returns
True if the value of BATTERY2MIN_THRESHOLD is non-zero
- Return type
boolean
- set_battery2min_threshold()
Set the value of the bit in the BATTERY2MIN_THRESHOLD field to 1
- unset_battery2min_threshold()
Set the value of the bits in the BATTERY2MIN_THRESHOLD field to 0
- is_battery2threshold1_set()
- Returns
True if the value of BATTERY2THRESHOLD1 is non-zero
- Return type
boolean
- set_battery2threshold1()
Set the value of the bit in the BATTERY2THRESHOLD1 field to 1
- unset_battery2threshold1()
Set the value of the bits in the BATTERY2THRESHOLD1 field to 0
- is_battery2threshold2_set()
- Returns
True if the value of BATTERY2THRESHOLD2 is non-zero
- Return type
boolean
- set_battery2threshold2()
Set the value of the bit in the BATTERY2THRESHOLD2 field to 1
- unset_battery2threshold2()
Set the value of the bits in the BATTERY2THRESHOLD2 field to 0
- is_battery2threshold3_set()
- Returns
True if the value of BATTERY2THRESHOLD3 is non-zero
- Return type
boolean
- set_battery2threshold3()
Set the value of the bit in the BATTERY2THRESHOLD3 field to 1
- unset_battery2threshold3()
Set the value of the bits in the BATTERY2THRESHOLD3 field to 0
- is_battery3min_threshold_set()
- Returns
True if the value of BATTERY3MIN_THRESHOLD is non-zero
- Return type
boolean
- set_battery3min_threshold()
Set the value of the bit in the BATTERY3MIN_THRESHOLD field to 1
- unset_battery3min_threshold()
Set the value of the bits in the BATTERY3MIN_THRESHOLD field to 0
- is_battery3threshold1_set()
- Returns
True if the value of BATTERY3THRESHOLD1 is non-zero
- Return type
boolean
- set_battery3threshold1()
Set the value of the bit in the BATTERY3THRESHOLD1 field to 1
- unset_battery3threshold1()
Set the value of the bits in the BATTERY3THRESHOLD1 field to 0
- is_battery3threshold2_set()
- Returns
True if the value of BATTERY3THRESHOLD2 is non-zero
- Return type
boolean
- set_battery3threshold2()
Set the value of the bit in the BATTERY3THRESHOLD2 field to 1
- unset_battery3threshold2()
Set the value of the bits in the BATTERY3THRESHOLD2 field to 0
- is_battery3threshold3_set()
- Returns
True if the value of BATTERY3THRESHOLD3 is non-zero
- Return type
boolean
- set_battery3threshold3()
Set the value of the bit in the BATTERY3THRESHOLD3 field to 1
- unset_battery3threshold3()
Set the value of the bits in the BATTERY3THRESHOLD3 field to 0
- is_mains_power_supply_lost_set()
- Returns
True if the value of MAINS_POWER_SUPPLY_LOST is non-zero
- Return type
boolean
- set_mains_power_supply_lost()
Set the value of the bit in the MAINS_POWER_SUPPLY_LOST field to 1
- unset_mains_power_supply_lost()
Set the value of the bits in the MAINS_POWER_SUPPLY_LOST field to 0