PowerConfiguration

class st.zigbee.zcl.clusters.PowerConfiguration
ID: number

0x0001 the ID of this cluster

NAME: str

“PowerConfiguration” the name of this cluster

attributes: st.zigbee.zcl.clusters.PowerConfigurationServerAttributes or st.zigbee.zcl.clusters.PowerConfigurationClientAttributes
commands: st.zigbee.zcl.clusters.PowerConfigurationServerCommands or st.zigbee.zcl.clusters.PowerConfigurationClientCommands
types: st.zigbee.zcl.clusters.PowerConfigurationTypes

PowerConfiguration Attributes

class st.zigbee.zcl.clusters.PowerConfiguration.MainsVoltage
ID: number

0x0000 the ID of this attribute

NAME: str

“MainsVoltage” the name of this attribute

data_type: st.zigbee.data_types.Uint16

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint16 object of this attribute with any additional features provided for the attribute

This is also usable with the MainsVoltage(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint16

Return type

st.zigbee.data_types.Uint16

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint16) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.MainsFrequency
ID: number

0x0001 the ID of this attribute

NAME: str

“MainsFrequency” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the MainsFrequency(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.MainsAlarmMask
ID: number

0x0010 the ID of this attribute

NAME: str

“MainsAlarmMask” the name of this attribute

data_type: st.zigbee.data_types.Bitmap8

the data type of this attribute

MAINS_VOLTAGE_TOO_LOW: number

1

MAINS_VOLTAGE_TOO_HIGH: number

2

MAINS_POWER_SUPPLY_LOST: number

4

is_mains_voltage_too_low_set()
Returns

True if the value of MAINS_VOLTAGE_TOO_LOW is non-zero

Return type

boolean

set_mains_voltage_too_low()

Set the value of the bit in the MAINS_VOLTAGE_TOO_LOW field to 1

unset_mains_voltage_too_low()

Set the value of the bits in the MAINS_VOLTAGE_TOO_LOW field to 0

is_mains_voltage_too_high_set()
Returns

True if the value of MAINS_VOLTAGE_TOO_HIGH is non-zero

Return type

boolean

set_mains_voltage_too_high()

Set the value of the bit in the MAINS_VOLTAGE_TOO_HIGH field to 1

unset_mains_voltage_too_high()

Set the value of the bits in the MAINS_VOLTAGE_TOO_HIGH field to 0

is_mains_power_supply_lost_set()
Returns

True if the value of MAINS_POWER_SUPPLY_LOST is non-zero

Return type

boolean

set_mains_power_supply_lost()

Set the value of the bit in the MAINS_POWER_SUPPLY_LOST field to 1

unset_mains_power_supply_lost()

Set the value of the bits in the MAINS_POWER_SUPPLY_LOST field to 0

augment_type(base_type_obj)

Add additional functionality to the base type object

Parameters

base_type_obj (st.zigbee.data_types.Bitmap8) – the base data type object to add functionality to

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Bitmap8 object of this attribute with any additional features provided for the attribute

This is also usable with the MainsAlarmMask(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Bitmap8

Return type

st.zigbee.data_types.Bitmap8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.MainsVoltageMinThreshold
ID: number

0x0011 the ID of this attribute

NAME: str

“MainsVoltageMinThreshold” the name of this attribute

data_type: st.zigbee.data_types.Uint16

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint16 object of this attribute with any additional features provided for the attribute

This is also usable with the MainsVoltageMinThreshold(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint16

Return type

st.zigbee.data_types.Uint16

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint16) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.MainsVoltageMaxThreshold
ID: number

0x0012 the ID of this attribute

NAME: str

“MainsVoltageMaxThreshold” the name of this attribute

data_type: st.zigbee.data_types.Uint16

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint16 object of this attribute with any additional features provided for the attribute

This is also usable with the MainsVoltageMaxThreshold(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint16

Return type

st.zigbee.data_types.Uint16

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint16) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.MainsVoltageDwellTripPoint
ID: number

0x0013 the ID of this attribute

NAME: str

“MainsVoltageDwellTripPoint” the name of this attribute

data_type: st.zigbee.data_types.Uint16

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint16 object of this attribute with any additional features provided for the attribute

This is also usable with the MainsVoltageDwellTripPoint(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint16

Return type

st.zigbee.data_types.Uint16

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint16) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.BatteryVoltage
ID: number

0x0020 the ID of this attribute

NAME: str

“BatteryVoltage” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the BatteryVoltage(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.BatteryPercentageRemaining
ID: number

0x0021 the ID of this attribute

NAME: str

“BatteryPercentageRemaining” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the BatteryPercentageRemaining(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.BatteryManufacturer
ID: number

0x0030 the ID of this attribute

NAME: str

“BatteryManufacturer” the name of this attribute

data_type: st.zigbee.data_types.CharString

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a CharString object of this attribute with any additional features provided for the attribute

This is also usable with the BatteryManufacturer(…) syntax

Parameters

vararg (vararg) – the values needed to construct a CharString

Return type

st.zigbee.data_types.CharString

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.CharString) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.BatterySize
ID: number

0x0031 the ID of this attribute

NAME: str

“BatterySize” the name of this attribute

data_type: st.zigbee.zcl.clusters.PowerConfiguration.types.BatterySize

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a BatterySizeType object of this attribute with any additional features provided for the attribute

This is also usable with the BatterySize(…) syntax

Parameters

vararg (vararg) – the values needed to construct a BatterySizeType

Return type

st.zigbee.zcl.clusters.PowerConfiguration.types.BatterySize

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.zcl.clusters.PowerConfiguration.types.BatterySize) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.BatteryAHrRating
ID: number

0x0032 the ID of this attribute

NAME: str

“BatteryAHrRating” the name of this attribute

data_type: st.zigbee.data_types.Uint16

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint16 object of this attribute with any additional features provided for the attribute

This is also usable with the BatteryAHrRating(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint16

Return type

st.zigbee.data_types.Uint16

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint16) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.BatteryQuantity
ID: number

0x0033 the ID of this attribute

NAME: str

“BatteryQuantity” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the BatteryQuantity(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.BatteryRatedVoltage
ID: number

0x0034 the ID of this attribute

NAME: str

“BatteryRatedVoltage” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the BatteryRatedVoltage(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.BatteryAlarmMask
ID: number

0x0035 the ID of this attribute

NAME: str

“BatteryAlarmMask” the name of this attribute

data_type: st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmMask

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a BatteryAlarmMaskType object of this attribute with any additional features provided for the attribute

This is also usable with the BatteryAlarmMask(…) syntax

Parameters

vararg (vararg) – the values needed to construct a BatteryAlarmMaskType

Return type

st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmMask

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmMask) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.BatteryVoltageMinThreshold
ID: number

0x0036 the ID of this attribute

NAME: str

“BatteryVoltageMinThreshold” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the BatteryVoltageMinThreshold(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.BatteryVoltageThreshold1
ID: number

0x0037 the ID of this attribute

NAME: str

“BatteryVoltageThreshold1” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the BatteryVoltageThreshold1(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.BatteryVoltageThreshold2
ID: number

0x0038 the ID of this attribute

NAME: str

“BatteryVoltageThreshold2” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the BatteryVoltageThreshold2(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.BatteryVoltageThreshold3
ID: number

0x0039 the ID of this attribute

NAME: str

“BatteryVoltageThreshold3” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the BatteryVoltageThreshold3(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.BatteryPercentageMinThreshold
ID: number

0x003A the ID of this attribute

NAME: str

“BatteryPercentageMinThreshold” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the BatteryPercentageMinThreshold(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.BatteryPercentageThreshold1
ID: number

0x003B the ID of this attribute

NAME: str

“BatteryPercentageThreshold1” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the BatteryPercentageThreshold1(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.BatteryPercentageThreshold2
ID: number

0x003C the ID of this attribute

NAME: str

“BatteryPercentageThreshold2” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the BatteryPercentageThreshold2(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.BatteryPercentageThreshold3
ID: number

0x003D the ID of this attribute

NAME: str

“BatteryPercentageThreshold3” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the BatteryPercentageThreshold3(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.BatteryAlarmState
ID: number

0x003E the ID of this attribute

NAME: str

“BatteryAlarmState” the name of this attribute

data_type: st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmState

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a BatteryAlarmStateType object of this attribute with any additional features provided for the attribute

This is also usable with the BatteryAlarmState(…) syntax

Parameters

vararg (vararg) – the values needed to construct a BatteryAlarmStateType

Return type

st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmState

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmState) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.Battery2Voltage
ID: number

0x0040 the ID of this attribute

NAME: str

“Battery2Voltage” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the Battery2Voltage(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.Battery2PercentageRemaining
ID: number

0x0041 the ID of this attribute

NAME: str

“Battery2PercentageRemaining” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the Battery2PercentageRemaining(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.Battery2Manufacturer
ID: number

0x0050 the ID of this attribute

NAME: str

“Battery2Manufacturer” the name of this attribute

data_type: st.zigbee.data_types.CharString

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a CharString object of this attribute with any additional features provided for the attribute

This is also usable with the Battery2Manufacturer(…) syntax

Parameters

vararg (vararg) – the values needed to construct a CharString

Return type

st.zigbee.data_types.CharString

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.CharString) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.Battery2Size
ID: number

0x0051 the ID of this attribute

NAME: str

“Battery2Size” the name of this attribute

data_type: st.zigbee.zcl.clusters.PowerConfiguration.types.BatterySize

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a BatterySizeType object of this attribute with any additional features provided for the attribute

This is also usable with the Battery2Size(…) syntax

Parameters

vararg (vararg) – the values needed to construct a BatterySizeType

Return type

st.zigbee.zcl.clusters.PowerConfiguration.types.BatterySize

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.zcl.clusters.PowerConfiguration.types.BatterySize) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.Battery2AHrRating
ID: number

0x0052 the ID of this attribute

NAME: str

“Battery2AHrRating” the name of this attribute

data_type: st.zigbee.data_types.Uint16

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint16 object of this attribute with any additional features provided for the attribute

This is also usable with the Battery2AHrRating(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint16

Return type

st.zigbee.data_types.Uint16

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint16) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.Battery2Quantity
ID: number

0x0053 the ID of this attribute

NAME: str

“Battery2Quantity” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the Battery2Quantity(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.Battery2RatedVoltage
ID: number

0x0054 the ID of this attribute

NAME: str

“Battery2RatedVoltage” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the Battery2RatedVoltage(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.Battery2AlarmMask
ID: number

0x0055 the ID of this attribute

NAME: str

“Battery2AlarmMask” the name of this attribute

data_type: st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmMask

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a BatteryAlarmMaskType object of this attribute with any additional features provided for the attribute

This is also usable with the Battery2AlarmMask(…) syntax

Parameters

vararg (vararg) – the values needed to construct a BatteryAlarmMaskType

Return type

st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmMask

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmMask) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.Battery2VoltageMinThreshold
ID: number

0x0056 the ID of this attribute

NAME: str

“Battery2VoltageMinThreshold” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the Battery2VoltageMinThreshold(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.Battery2VoltageThreshold1
ID: number

0x0057 the ID of this attribute

NAME: str

“Battery2VoltageThreshold1” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the Battery2VoltageThreshold1(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.Battery2VoltageThreshold2
ID: number

0x0058 the ID of this attribute

NAME: str

“Battery2VoltageThreshold2” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the Battery2VoltageThreshold2(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.Battery2VoltageThreshold3
ID: number

0x0059 the ID of this attribute

NAME: str

“Battery2VoltageThreshold3” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the Battery2VoltageThreshold3(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.Battery2PercentageMinThreshold
ID: number

0x005A the ID of this attribute

NAME: str

“Battery2PercentageMinThreshold” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the Battery2PercentageMinThreshold(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.Battery2PercentageThreshold1
ID: number

0x005B the ID of this attribute

NAME: str

“Battery2PercentageThreshold1” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the Battery2PercentageThreshold1(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.Battery2PercentageThreshold2
ID: number

0x005C the ID of this attribute

NAME: str

“Battery2PercentageThreshold2” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the Battery2PercentageThreshold2(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.Battery2PercentageThreshold3
ID: number

0x005D the ID of this attribute

NAME: str

“Battery2PercentageThreshold3” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the Battery2PercentageThreshold3(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.Battery2AlarmState
ID: number

0x005E the ID of this attribute

NAME: str

“Battery2AlarmState” the name of this attribute

data_type: st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmState

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a BatteryAlarmStateType object of this attribute with any additional features provided for the attribute

This is also usable with the Battery2AlarmState(…) syntax

Parameters

vararg (vararg) – the values needed to construct a BatteryAlarmStateType

Return type

st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmState

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmState) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.Battery3Voltage
ID: number

0x0060 the ID of this attribute

NAME: str

“Battery3Voltage” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the Battery3Voltage(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.Battery3PercentageRemaining
ID: number

0x0061 the ID of this attribute

NAME: str

“Battery3PercentageRemaining” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the Battery3PercentageRemaining(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.Battery3Manufacturer
ID: number

0x0070 the ID of this attribute

NAME: str

“Battery3Manufacturer” the name of this attribute

data_type: st.zigbee.data_types.CharString

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a CharString object of this attribute with any additional features provided for the attribute

This is also usable with the Battery3Manufacturer(…) syntax

Parameters

vararg (vararg) – the values needed to construct a CharString

Return type

st.zigbee.data_types.CharString

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.CharString) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.Battery3Size
ID: number

0x0071 the ID of this attribute

NAME: str

“Battery3Size” the name of this attribute

data_type: st.zigbee.zcl.clusters.PowerConfiguration.types.BatterySize

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a BatterySizeType object of this attribute with any additional features provided for the attribute

This is also usable with the Battery3Size(…) syntax

Parameters

vararg (vararg) – the values needed to construct a BatterySizeType

Return type

st.zigbee.zcl.clusters.PowerConfiguration.types.BatterySize

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.zcl.clusters.PowerConfiguration.types.BatterySize) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.Battery3AHrRating
ID: number

0x0072 the ID of this attribute

NAME: str

“Battery3AHrRating” the name of this attribute

data_type: st.zigbee.data_types.Uint16

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint16 object of this attribute with any additional features provided for the attribute

This is also usable with the Battery3AHrRating(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint16

Return type

st.zigbee.data_types.Uint16

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint16) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.Battery3Quantity
ID: number

0x0073 the ID of this attribute

NAME: str

“Battery3Quantity” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the Battery3Quantity(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.Battery3RatedVoltage
ID: number

0x0074 the ID of this attribute

NAME: str

“Battery3RatedVoltage” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the Battery3RatedVoltage(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.Battery3AlarmMask
ID: number

0x0075 the ID of this attribute

NAME: str

“Battery3AlarmMask” the name of this attribute

data_type: st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmMask

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a BatteryAlarmMaskType object of this attribute with any additional features provided for the attribute

This is also usable with the Battery3AlarmMask(…) syntax

Parameters

vararg (vararg) – the values needed to construct a BatteryAlarmMaskType

Return type

st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmMask

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmMask) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.Battery3VoltageMinThreshold
ID: number

0x0076 the ID of this attribute

NAME: str

“Battery3VoltageMinThreshold” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the Battery3VoltageMinThreshold(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.Battery3VoltageThreshold1
ID: number

0x0077 the ID of this attribute

NAME: str

“Battery3VoltageThreshold1” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the Battery3VoltageThreshold1(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.Battery3VoltageThreshold2
ID: number

0x0078 the ID of this attribute

NAME: str

“Battery3VoltageThreshold2” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the Battery3VoltageThreshold2(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.Battery3VoltageThreshold3
ID: number

0x0079 the ID of this attribute

NAME: str

“Battery3VoltageThreshold3” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the Battery3VoltageThreshold3(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.Battery3PercentageMinThreshold
ID: number

0x007A the ID of this attribute

NAME: str

“Battery3PercentageMinThreshold” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the Battery3PercentageMinThreshold(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.Battery3PercentageThreshold1
ID: number

0x007B the ID of this attribute

NAME: str

“Battery3PercentageThreshold1” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the Battery3PercentageThreshold1(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.Battery3PercentageThreshold2
ID: number

0x007C the ID of this attribute

NAME: str

“Battery3PercentageThreshold2” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the Battery3PercentageThreshold2(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.Battery3PercentageThreshold3
ID: number

0x007D the ID of this attribute

NAME: str

“Battery3PercentageThreshold3” the name of this attribute

data_type: st.zigbee.data_types.Uint8

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a Uint8 object of this attribute with any additional features provided for the attribute

This is also usable with the Battery3PercentageThreshold3(…) syntax

Parameters

vararg (vararg) – the values needed to construct a Uint8

Return type

st.zigbee.data_types.Uint8

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

write(device, value)

Write a value to this attribute on a device

Parameters
set_parent_cluster(cluster)
Parameters

cluster (any) –

class st.zigbee.zcl.clusters.PowerConfiguration.Battery3AlarmState
ID: number

0x007E the ID of this attribute

NAME: str

“Battery3AlarmState” the name of this attribute

data_type: st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmState

the data type of this attribute

augment_type(base_type_obj)
Parameters

base_type_obj (any) –

build_test_attr_report(device, data)

Build a Rx Zigbee message as if a device reported this attribute

Parameters
Returns

containing an AttributeReport body

Return type

st.zigbee.ZigbeeMessageRx

build_test_read_attr_response(device, data)

Build a Rx Zigbee message as if a device sent a read response for this attribute

Parameters
Returns

containing an ReadAttributeResponse body

Return type

st.zigbee.ZigbeeMessageRx

new_value(...)

Create a BatteryAlarmStateType object of this attribute with any additional features provided for the attribute

This is also usable with the Battery3AlarmState(…) syntax

Parameters

vararg (vararg) – the values needed to construct a BatteryAlarmStateType

Return type

st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmState

read(device)

Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device

Parameters

device (st.zigbee.Device) –

Returns

containing a ReadAttribute body

Return type

st.zigbee.ZigbeeMessageTx

configure_reporting(device, min_rep_int, max_rep_int, rep_change)

Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device

Parameters
  • device (st.zigbee.Device) –

  • min_rep_int (number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attribute

  • max_rep_int (number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute

  • rep_change (st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmState) – The amount of change of the attribute to trigger a report

Returns

containing a ConfigureReporting body

Return type

st.zigbee.ZigbeeMessageTx

set_parent_cluster(cluster)
Parameters

cluster (any) –

PowerConfiguration Commands

PowerConfiguration Types

class st.zigbee.zcl.clusters.PowerConfiguration.types.BatterySize: st.zigbee.data_types.Enum8
byte_length: number

1

NO_BATTERY: number

0

BUILT_IN: number

1

OTHER: number

2

AA: number

3

AAA: number

4

C: number

5

D: number

6

CR2: number

7

CR123A: number

8

UNKNOWN: number

255

class st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmMask: st.zigbee.data_types.Bitmap8
byte_length: number

1

BATTERY_VOLTAGE_TOO_LOW: number

1

BATTERY_ALARM1: number

2

BATTERY_ALARM2: number

4

BATTERY_ALARM3: number

8

is_battery_voltage_too_low_set()
Returns

True if the value of BATTERY_VOLTAGE_TOO_LOW is non-zero

Return type

boolean

set_battery_voltage_too_low()

Set the value of the bit in the BATTERY_VOLTAGE_TOO_LOW field to 1

unset_battery_voltage_too_low()

Set the value of the bits in the BATTERY_VOLTAGE_TOO_LOW field to 0

is_battery_alarm1_set()
Returns

True if the value of BATTERY_ALARM1 is non-zero

Return type

boolean

set_battery_alarm1()

Set the value of the bit in the BATTERY_ALARM1 field to 1

unset_battery_alarm1()

Set the value of the bits in the BATTERY_ALARM1 field to 0

is_battery_alarm2_set()
Returns

True if the value of BATTERY_ALARM2 is non-zero

Return type

boolean

set_battery_alarm2()

Set the value of the bit in the BATTERY_ALARM2 field to 1

unset_battery_alarm2()

Set the value of the bits in the BATTERY_ALARM2 field to 0

is_battery_alarm3_set()
Returns

True if the value of BATTERY_ALARM3 is non-zero

Return type

boolean

set_battery_alarm3()

Set the value of the bit in the BATTERY_ALARM3 field to 1

unset_battery_alarm3()

Set the value of the bits in the BATTERY_ALARM3 field to 0

class st.zigbee.zcl.clusters.PowerConfiguration.types.BatteryAlarmState: st.zigbee.data_types.Bitmap32
byte_length: number

4

BATTERY1MIN_THRESHOLD: number

1

BATTERY1THRESHOLD1: number

2

BATTERY1THRESHOLD2: number

4

BATTERY1THRESHOLD3: number

8

BATTERY2MIN_THRESHOLD: number

1024

BATTERY2THRESHOLD1: number

2048

BATTERY2THRESHOLD2: number

4096

BATTERY2THRESHOLD3: number

8192

BATTERY3MIN_THRESHOLD: number

1048576

BATTERY3THRESHOLD1: number

2097152

BATTERY3THRESHOLD2: number

4194304

BATTERY3THRESHOLD3: number

8388608

MAINS_POWER_SUPPLY_LOST: number

1073741824

is_battery1min_threshold_set()
Returns

True if the value of BATTERY1MIN_THRESHOLD is non-zero

Return type

boolean

set_battery1min_threshold()

Set the value of the bit in the BATTERY1MIN_THRESHOLD field to 1

unset_battery1min_threshold()

Set the value of the bits in the BATTERY1MIN_THRESHOLD field to 0

is_battery1threshold1_set()
Returns

True if the value of BATTERY1THRESHOLD1 is non-zero

Return type

boolean

set_battery1threshold1()

Set the value of the bit in the BATTERY1THRESHOLD1 field to 1

unset_battery1threshold1()

Set the value of the bits in the BATTERY1THRESHOLD1 field to 0

is_battery1threshold2_set()
Returns

True if the value of BATTERY1THRESHOLD2 is non-zero

Return type

boolean

set_battery1threshold2()

Set the value of the bit in the BATTERY1THRESHOLD2 field to 1

unset_battery1threshold2()

Set the value of the bits in the BATTERY1THRESHOLD2 field to 0

is_battery1threshold3_set()
Returns

True if the value of BATTERY1THRESHOLD3 is non-zero

Return type

boolean

set_battery1threshold3()

Set the value of the bit in the BATTERY1THRESHOLD3 field to 1

unset_battery1threshold3()

Set the value of the bits in the BATTERY1THRESHOLD3 field to 0

is_battery2min_threshold_set()
Returns

True if the value of BATTERY2MIN_THRESHOLD is non-zero

Return type

boolean

set_battery2min_threshold()

Set the value of the bit in the BATTERY2MIN_THRESHOLD field to 1

unset_battery2min_threshold()

Set the value of the bits in the BATTERY2MIN_THRESHOLD field to 0

is_battery2threshold1_set()
Returns

True if the value of BATTERY2THRESHOLD1 is non-zero

Return type

boolean

set_battery2threshold1()

Set the value of the bit in the BATTERY2THRESHOLD1 field to 1

unset_battery2threshold1()

Set the value of the bits in the BATTERY2THRESHOLD1 field to 0

is_battery2threshold2_set()
Returns

True if the value of BATTERY2THRESHOLD2 is non-zero

Return type

boolean

set_battery2threshold2()

Set the value of the bit in the BATTERY2THRESHOLD2 field to 1

unset_battery2threshold2()

Set the value of the bits in the BATTERY2THRESHOLD2 field to 0

is_battery2threshold3_set()
Returns

True if the value of BATTERY2THRESHOLD3 is non-zero

Return type

boolean

set_battery2threshold3()

Set the value of the bit in the BATTERY2THRESHOLD3 field to 1

unset_battery2threshold3()

Set the value of the bits in the BATTERY2THRESHOLD3 field to 0

is_battery3min_threshold_set()
Returns

True if the value of BATTERY3MIN_THRESHOLD is non-zero

Return type

boolean

set_battery3min_threshold()

Set the value of the bit in the BATTERY3MIN_THRESHOLD field to 1

unset_battery3min_threshold()

Set the value of the bits in the BATTERY3MIN_THRESHOLD field to 0

is_battery3threshold1_set()
Returns

True if the value of BATTERY3THRESHOLD1 is non-zero

Return type

boolean

set_battery3threshold1()

Set the value of the bit in the BATTERY3THRESHOLD1 field to 1

unset_battery3threshold1()

Set the value of the bits in the BATTERY3THRESHOLD1 field to 0

is_battery3threshold2_set()
Returns

True if the value of BATTERY3THRESHOLD2 is non-zero

Return type

boolean

set_battery3threshold2()

Set the value of the bit in the BATTERY3THRESHOLD2 field to 1

unset_battery3threshold2()

Set the value of the bits in the BATTERY3THRESHOLD2 field to 0

is_battery3threshold3_set()
Returns

True if the value of BATTERY3THRESHOLD3 is non-zero

Return type

boolean

set_battery3threshold3()

Set the value of the bit in the BATTERY3THRESHOLD3 field to 1

unset_battery3threshold3()

Set the value of the bits in the BATTERY3THRESHOLD3 field to 0

is_mains_power_supply_lost_set()
Returns

True if the value of MAINS_POWER_SUPPLY_LOST is non-zero

Return type

boolean

set_mains_power_supply_lost()

Set the value of the bit in the MAINS_POWER_SUPPLY_LOST field to 1

unset_mains_power_supply_lost()

Set the value of the bits in the MAINS_POWER_SUPPLY_LOST field to 0