BarrierControl¶
- class st.zigbee.zcl.clusters.BarrierControl¶
- ID: number¶
0x0103 the ID of this cluster
- NAME: str¶
“BarrierControl” the name of this cluster
- attributes: st.zigbee.zcl.clusters.BarrierControlServerAttributes or st.zigbee.zcl.clusters.BarrierControlClientAttributes¶
- commands: st.zigbee.zcl.clusters.BarrierControlServerCommands or st.zigbee.zcl.clusters.BarrierControlClientCommands¶
- types: st.zigbee.zcl.clusters.BarrierControlTypes¶
BarrierControl Attributes¶
- class st.zigbee.zcl.clusters.BarrierControl.MovingState¶
- ID: number¶
0x0001 the ID of this attribute
- NAME: str¶
“MovingState” the name of this attribute
- data_type: st.zigbee.data_types.Enum8¶
the data type of this attribute
- STOPPED: number¶
0
- CLOSING: number¶
1
- OPENING: number¶
2
- augment_type(base_type_obj)¶
Add additional functionality to the base type object
- Parameters:
base_type_obj (
st.zigbee.data_types.Enum8) – the base data type object to add functionality to
- build_test_attr_report(device, data)¶
Build a Rx Zigbee message as if a device reported this attribute
- Parameters:
device (
st.zigbee.Device)data (
st.zigbee.data_types.Enum8) – the attribute value
- Returns:
containing an AttributeReport body
- Return type:
- build_test_read_attr_response(device, data)¶
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters:
device (
st.zigbee.Device)data (
st.zigbee.data_types.Enum8) – the attribute value
- Returns:
containing an ReadAttributeResponse body
- Return type:
- new_value(...)¶
Create a Enum8 object of this attribute with any additional features provided for the attribute
This is also usable with the MovingState(…) syntax
- Parameters:
vararg (
vararg) – the values needed to construct a Enum8- Return type:
- read(device)¶
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters:
device (
st.zigbee.Device)- Returns:
containing a ReadAttribute body
- Return type:
- configure_reporting(device, min_rep_int, max_rep_int)¶
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters:
device (
st.zigbee.Device)min_rep_int (
number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute
- Returns:
containing a ConfigureReporting body
- Return type:
- class st.zigbee.zcl.clusters.BarrierControl.SafetyStatus¶
- ID: number¶
0x0002 the ID of this attribute
- NAME: str¶
“SafetyStatus” the name of this attribute
- data_type: st.zigbee.data_types.Bitmap16¶
the data type of this attribute
- REMOTE_LOCKOUT: number¶
1
- TAMPER_DETECTED: number¶
2
- FAILED_COMMUNICATION: number¶
4
- POSITION_FAILURE: number¶
8
- is_remote_lockout_set()¶
- Returns:
True if the value of REMOTE_LOCKOUT is non-zero
- Return type:
boolean
- set_remote_lockout()¶
Set the value of the bit in the REMOTE_LOCKOUT field to 1
- unset_remote_lockout()¶
Set the value of the bits in the REMOTE_LOCKOUT field to 0
- is_tamper_detected_set()¶
- Returns:
True if the value of TAMPER_DETECTED is non-zero
- Return type:
boolean
- set_tamper_detected()¶
Set the value of the bit in the TAMPER_DETECTED field to 1
- unset_tamper_detected()¶
Set the value of the bits in the TAMPER_DETECTED field to 0
- is_failed_communication_set()¶
- Returns:
True if the value of FAILED_COMMUNICATION is non-zero
- Return type:
boolean
- set_failed_communication()¶
Set the value of the bit in the FAILED_COMMUNICATION field to 1
- unset_failed_communication()¶
Set the value of the bits in the FAILED_COMMUNICATION field to 0
- is_position_failure_set()¶
- Returns:
True if the value of POSITION_FAILURE is non-zero
- Return type:
boolean
- set_position_failure()¶
Set the value of the bit in the POSITION_FAILURE field to 1
- unset_position_failure()¶
Set the value of the bits in the POSITION_FAILURE field to 0
- augment_type(base_type_obj)¶
Add additional functionality to the base type object
- Parameters:
base_type_obj (
st.zigbee.data_types.Bitmap16) – the base data type object to add functionality to
- build_test_attr_report(device, data)¶
Build a Rx Zigbee message as if a device reported this attribute
- Parameters:
device (
st.zigbee.Device)data (
st.zigbee.data_types.Bitmap16) – the attribute value
- Returns:
containing an AttributeReport body
- Return type:
- build_test_read_attr_response(device, data)¶
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters:
device (
st.zigbee.Device)data (
st.zigbee.data_types.Bitmap16) – the attribute value
- Returns:
containing an ReadAttributeResponse body
- Return type:
- new_value(...)¶
Create a Bitmap16 object of this attribute with any additional features provided for the attribute
This is also usable with the SafetyStatus(…) syntax
- Parameters:
vararg (
vararg) – the values needed to construct a Bitmap16- Return type:
- read(device)¶
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters:
device (
st.zigbee.Device)- Returns:
containing a ReadAttribute body
- Return type:
- configure_reporting(device, min_rep_int, max_rep_int)¶
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters:
device (
st.zigbee.Device)min_rep_int (
number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute
- Returns:
containing a ConfigureReporting body
- Return type:
- class st.zigbee.zcl.clusters.BarrierControl.Capabilities¶
- ID: number¶
0x0003 the ID of this attribute
- NAME: str¶
“Capabilities” the name of this attribute
- data_type: st.zigbee.data_types.Bitmap8¶
the data type of this attribute
- PARTIAL_BARRIER: number¶
1
- is_partial_barrier_set()¶
- Returns:
True if the value of PARTIAL_BARRIER is non-zero
- Return type:
boolean
- set_partial_barrier()¶
Set the value of the bit in the PARTIAL_BARRIER field to 1
- unset_partial_barrier()¶
Set the value of the bits in the PARTIAL_BARRIER field to 0
- augment_type(base_type_obj)¶
Add additional functionality to the base type object
- Parameters:
base_type_obj (
st.zigbee.data_types.Bitmap8) – the base data type object to add functionality to
- build_test_attr_report(device, data)¶
Build a Rx Zigbee message as if a device reported this attribute
- Parameters:
device (
st.zigbee.Device)data (
st.zigbee.data_types.Bitmap8) – the attribute value
- Returns:
containing an AttributeReport body
- Return type:
- build_test_read_attr_response(device, data)¶
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters:
device (
st.zigbee.Device)data (
st.zigbee.data_types.Bitmap8) – the attribute value
- Returns:
containing an ReadAttributeResponse body
- Return type:
- new_value(...)¶
Create a Bitmap8 object of this attribute with any additional features provided for the attribute
This is also usable with the Capabilities(…) syntax
- Parameters:
vararg (
vararg) – the values needed to construct a Bitmap8- Return type:
- read(device)¶
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters:
device (
st.zigbee.Device)- Returns:
containing a ReadAttribute body
- Return type:
- configure_reporting(device, min_rep_int, max_rep_int)¶
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters:
device (
st.zigbee.Device)min_rep_int (
number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attribute
- Returns:
containing a ConfigureReporting body
- Return type:
- class st.zigbee.zcl.clusters.BarrierControl.OpenEvents¶
- ID: number¶
0x0004 the ID of this attribute
- NAME: str¶
“OpenEvents” the name of this attribute
- data_type: st.zigbee.data_types.Uint16¶
the data type of this attribute
- augment_type(base_type_obj)¶
- Parameters:
base_type_obj (
any)
- build_test_attr_report(device, data)¶
Build a Rx Zigbee message as if a device reported this attribute
- Parameters:
device (
st.zigbee.Device)data (
st.zigbee.data_types.Uint16) – the attribute value
- Returns:
containing an AttributeReport body
- Return type:
- build_test_read_attr_response(device, data)¶
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters:
device (
st.zigbee.Device)data (
st.zigbee.data_types.Uint16) – the attribute value
- Returns:
containing an ReadAttributeResponse body
- Return type:
- new_value(...)¶
Create a Uint16 object of this attribute with any additional features provided for the attribute
This is also usable with the OpenEvents(…) syntax
- Parameters:
vararg (
vararg) – the values needed to construct a Uint16- Return type:
- read(device)¶
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters:
device (
st.zigbee.Device)- Returns:
containing a ReadAttribute body
- Return type:
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)¶
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters:
device (
st.zigbee.Device)min_rep_int (
number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint16) – The amount of change of the attribute to trigger a report
- Returns:
containing a ConfigureReporting body
- Return type:
- write(device, value)¶
Write a value to this attribute on a device
- Parameters:
device (
st.zigbee.Device)value (
st.zigbee.data_types.Uint16) – the value to write
- class st.zigbee.zcl.clusters.BarrierControl.CloseEvents¶
- ID: number¶
0x0005 the ID of this attribute
- NAME: str¶
“CloseEvents” the name of this attribute
- data_type: st.zigbee.data_types.Uint16¶
the data type of this attribute
- augment_type(base_type_obj)¶
- Parameters:
base_type_obj (
any)
- build_test_attr_report(device, data)¶
Build a Rx Zigbee message as if a device reported this attribute
- Parameters:
device (
st.zigbee.Device)data (
st.zigbee.data_types.Uint16) – the attribute value
- Returns:
containing an AttributeReport body
- Return type:
- build_test_read_attr_response(device, data)¶
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters:
device (
st.zigbee.Device)data (
st.zigbee.data_types.Uint16) – the attribute value
- Returns:
containing an ReadAttributeResponse body
- Return type:
- new_value(...)¶
Create a Uint16 object of this attribute with any additional features provided for the attribute
This is also usable with the CloseEvents(…) syntax
- Parameters:
vararg (
vararg) – the values needed to construct a Uint16- Return type:
- read(device)¶
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters:
device (
st.zigbee.Device)- Returns:
containing a ReadAttribute body
- Return type:
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)¶
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters:
device (
st.zigbee.Device)min_rep_int (
number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint16) – The amount of change of the attribute to trigger a report
- Returns:
containing a ConfigureReporting body
- Return type:
- write(device, value)¶
Write a value to this attribute on a device
- Parameters:
device (
st.zigbee.Device)value (
st.zigbee.data_types.Uint16) – the value to write
- class st.zigbee.zcl.clusters.BarrierControl.CommandOpenEvents¶
- ID: number¶
0x0006 the ID of this attribute
- NAME: str¶
“CommandOpenEvents” the name of this attribute
- data_type: st.zigbee.data_types.Uint16¶
the data type of this attribute
- augment_type(base_type_obj)¶
- Parameters:
base_type_obj (
any)
- build_test_attr_report(device, data)¶
Build a Rx Zigbee message as if a device reported this attribute
- Parameters:
device (
st.zigbee.Device)data (
st.zigbee.data_types.Uint16) – the attribute value
- Returns:
containing an AttributeReport body
- Return type:
- build_test_read_attr_response(device, data)¶
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters:
device (
st.zigbee.Device)data (
st.zigbee.data_types.Uint16) – the attribute value
- Returns:
containing an ReadAttributeResponse body
- Return type:
- new_value(...)¶
Create a Uint16 object of this attribute with any additional features provided for the attribute
This is also usable with the CommandOpenEvents(…) syntax
- Parameters:
vararg (
vararg) – the values needed to construct a Uint16- Return type:
- read(device)¶
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters:
device (
st.zigbee.Device)- Returns:
containing a ReadAttribute body
- Return type:
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)¶
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters:
device (
st.zigbee.Device)min_rep_int (
number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint16) – The amount of change of the attribute to trigger a report
- Returns:
containing a ConfigureReporting body
- Return type:
- write(device, value)¶
Write a value to this attribute on a device
- Parameters:
device (
st.zigbee.Device)value (
st.zigbee.data_types.Uint16) – the value to write
- class st.zigbee.zcl.clusters.BarrierControl.CommandCloseEvents¶
- ID: number¶
0x0007 the ID of this attribute
- NAME: str¶
“CommandCloseEvents” the name of this attribute
- data_type: st.zigbee.data_types.Uint16¶
the data type of this attribute
- augment_type(base_type_obj)¶
- Parameters:
base_type_obj (
any)
- build_test_attr_report(device, data)¶
Build a Rx Zigbee message as if a device reported this attribute
- Parameters:
device (
st.zigbee.Device)data (
st.zigbee.data_types.Uint16) – the attribute value
- Returns:
containing an AttributeReport body
- Return type:
- build_test_read_attr_response(device, data)¶
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters:
device (
st.zigbee.Device)data (
st.zigbee.data_types.Uint16) – the attribute value
- Returns:
containing an ReadAttributeResponse body
- Return type:
- new_value(...)¶
Create a Uint16 object of this attribute with any additional features provided for the attribute
This is also usable with the CommandCloseEvents(…) syntax
- Parameters:
vararg (
vararg) – the values needed to construct a Uint16- Return type:
- read(device)¶
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters:
device (
st.zigbee.Device)- Returns:
containing a ReadAttribute body
- Return type:
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)¶
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters:
device (
st.zigbee.Device)min_rep_int (
number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint16) – The amount of change of the attribute to trigger a report
- Returns:
containing a ConfigureReporting body
- Return type:
- write(device, value)¶
Write a value to this attribute on a device
- Parameters:
device (
st.zigbee.Device)value (
st.zigbee.data_types.Uint16) – the value to write
- class st.zigbee.zcl.clusters.BarrierControl.OpenPeriod¶
- ID: number¶
0x0008 the ID of this attribute
- NAME: str¶
“OpenPeriod” the name of this attribute
- data_type: st.zigbee.data_types.Uint16¶
the data type of this attribute
- augment_type(base_type_obj)¶
- Parameters:
base_type_obj (
any)
- build_test_attr_report(device, data)¶
Build a Rx Zigbee message as if a device reported this attribute
- Parameters:
device (
st.zigbee.Device)data (
st.zigbee.data_types.Uint16) – the attribute value
- Returns:
containing an AttributeReport body
- Return type:
- build_test_read_attr_response(device, data)¶
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters:
device (
st.zigbee.Device)data (
st.zigbee.data_types.Uint16) – the attribute value
- Returns:
containing an ReadAttributeResponse body
- Return type:
- new_value(...)¶
Create a Uint16 object of this attribute with any additional features provided for the attribute
This is also usable with the OpenPeriod(…) syntax
- Parameters:
vararg (
vararg) – the values needed to construct a Uint16- Return type:
- read(device)¶
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters:
device (
st.zigbee.Device)- Returns:
containing a ReadAttribute body
- Return type:
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)¶
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters:
device (
st.zigbee.Device)min_rep_int (
number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint16) – The amount of change of the attribute to trigger a report
- Returns:
containing a ConfigureReporting body
- Return type:
- write(device, value)¶
Write a value to this attribute on a device
- Parameters:
device (
st.zigbee.Device)value (
st.zigbee.data_types.Uint16) – the value to write
- class st.zigbee.zcl.clusters.BarrierControl.ClosePeriod¶
- ID: number¶
0x0009 the ID of this attribute
- NAME: str¶
“ClosePeriod” the name of this attribute
- data_type: st.zigbee.data_types.Uint16¶
the data type of this attribute
- augment_type(base_type_obj)¶
- Parameters:
base_type_obj (
any)
- build_test_attr_report(device, data)¶
Build a Rx Zigbee message as if a device reported this attribute
- Parameters:
device (
st.zigbee.Device)data (
st.zigbee.data_types.Uint16) – the attribute value
- Returns:
containing an AttributeReport body
- Return type:
- build_test_read_attr_response(device, data)¶
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters:
device (
st.zigbee.Device)data (
st.zigbee.data_types.Uint16) – the attribute value
- Returns:
containing an ReadAttributeResponse body
- Return type:
- new_value(...)¶
Create a Uint16 object of this attribute with any additional features provided for the attribute
This is also usable with the ClosePeriod(…) syntax
- Parameters:
vararg (
vararg) – the values needed to construct a Uint16- Return type:
- read(device)¶
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters:
device (
st.zigbee.Device)- Returns:
containing a ReadAttribute body
- Return type:
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)¶
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters:
device (
st.zigbee.Device)min_rep_int (
number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint16) – The amount of change of the attribute to trigger a report
- Returns:
containing a ConfigureReporting body
- Return type:
- write(device, value)¶
Write a value to this attribute on a device
- Parameters:
device (
st.zigbee.Device)value (
st.zigbee.data_types.Uint16) – the value to write
- class st.zigbee.zcl.clusters.BarrierControl.BarrierPosition¶
- ID: number¶
0x000A the ID of this attribute
- NAME: str¶
“BarrierPosition” the name of this attribute
- data_type: st.zigbee.data_types.Uint8¶
the data type of this attribute
- augment_type(base_type_obj)¶
- Parameters:
base_type_obj (
any)
- build_test_attr_report(device, data)¶
Build a Rx Zigbee message as if a device reported this attribute
- Parameters:
device (
st.zigbee.Device)data (
st.zigbee.data_types.Uint8) – the attribute value
- Returns:
containing an AttributeReport body
- Return type:
- build_test_read_attr_response(device, data)¶
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters:
device (
st.zigbee.Device)data (
st.zigbee.data_types.Uint8) – the attribute value
- Returns:
containing an ReadAttributeResponse body
- Return type:
- new_value(...)¶
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the BarrierPosition(…) syntax
- Parameters:
vararg (
vararg) – the values needed to construct a Uint8- Return type:
- read(device)¶
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters:
device (
st.zigbee.Device)- Returns:
containing a ReadAttribute body
- Return type:
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)¶
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters:
device (
st.zigbee.Device)min_rep_int (
number or st.zigbee.data_types.Uint16) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8) – The amount of change of the attribute to trigger a report
- Returns:
containing a ConfigureReporting body
- Return type:
BarrierControl Commands¶
- class st.zigbee.zcl.clusters.BarrierControl.GoToPercent¶
- ID: number¶
0x00 the ID of this command
- NAME: str¶
“GoToPercent” the name of this command
- percent_open: st.zigbee.data_types.Uint8¶
- get_fields()¶
- static deserialize(buf)¶
Deserialize this command
- Parameters:
buf (
buf) – the bytes of the command body- Return type:
GoToPercent
- set_field_names()¶
- static build_test_rx(device, percent_open)¶
Build a version of this message as if it came from the device
- Parameters:
device (
st.zigbee.Device) – the device to build the message frompercent_open (
st.zigbee.data_types.Uint8)
- Returns:
The full Zigbee message containing this command body
- Return type:
- init(self, device, percent_open)¶
Initialize the GoToPercent command
- Parameters:
self (
GoToPercent) – the template class for this commanddevice (
st.zigbee.Device) – the device to build this message topercent_open (
st.zigbee.data_types.Uint8)
- Returns:
the full command addressed to the device
- Return type:
- class st.zigbee.zcl.clusters.BarrierControl.Stop¶
- ID: number¶
0x01 the ID of this command
- NAME: str¶
“Stop” the name of this command
- get_fields()¶
- static deserialize(buf)¶
Deserialize this command
- Parameters:
buf (
buf) – the bytes of the command body- Return type:
Stop
- set_field_names()¶
- static build_test_rx(device)¶
Build a version of this message as if it came from the device
- Parameters:
device (
st.zigbee.Device) – the device to build the message from- Returns:
The full Zigbee message containing this command body
- Return type:
- init(self, device)¶
Initialize the Stop command
- Parameters:
self (
Stop) – the template class for this commanddevice (
st.zigbee.Device) – the device to build this message to
- Returns:
the full command addressed to the device
- Return type: