WindowCovering
- class st.zigbee.zcl.clusters.WindowCovering
- ID: number
0x0102 the ID of this cluster
- NAME: str
“WindowCovering” the name of this cluster
- attributes: st.zigbee.zcl.clusters.WindowCoveringServerAttributes or st.zigbee.zcl.clusters.WindowCoveringClientAttributes
- commands: st.zigbee.zcl.clusters.WindowCoveringServerCommands or st.zigbee.zcl.clusters.WindowCoveringClientCommands
- types: st.zigbee.zcl.clusters.WindowCoveringTypes
WindowCovering Attributes
- class st.zigbee.zcl.clusters.WindowCovering.WindowCoveringType
- ID: number
0x0000 the ID of this attribute
- NAME: str
“WindowCoveringType” the name of this attribute
- data_type: st.zigbee.data_types.Enum8
the data type of this attribute
- ROLLERSHADE: number
0
- ROLLERSHADE2MOTOR: number
1
- ROLLERSHADE_EXTERIOR: number
2
- ROLLERSHADE_EXTERIOR2MOTOR: number
3
- DRAPERY: number
4
- AWNING: number
5
- SHUTTER: number
6
- TILT_BLIND_TILT_ONLY: number
7
- TILT_BLIND_LIFT_AND_TILT: number
8
- PROJECTOR_SCREEN: number
9
- augment_type(base_type_obj)
Add additional functionality to the base type object
- Parameters
base_type_obj (
st.zigbee.data_types.Enum8
) – the base data type object to add functionality to
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Enum8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Enum8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Enum8 object of this attribute with any additional features provided for the attribute
This is also usable with the WindowCoveringType(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Enum8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attribute
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.WindowCovering.PhysicalClosedLimitLift
- ID: number
0x0001 the ID of this attribute
- NAME: str
“PhysicalClosedLimitLift” the name of this attribute
- data_type: st.zigbee.data_types.Uint16
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint16 object of this attribute with any additional features provided for the attribute
This is also usable with the PhysicalClosedLimitLift(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint16- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint16
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.WindowCovering.PhysicalClosedLimitTilt
- ID: number
0x0002 the ID of this attribute
- NAME: str
“PhysicalClosedLimitTilt” the name of this attribute
- data_type: st.zigbee.data_types.Uint16
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint16 object of this attribute with any additional features provided for the attribute
This is also usable with the PhysicalClosedLimitTilt(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint16- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint16
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.WindowCovering.CurrentPositionLift
- ID: number
0x0003 the ID of this attribute
- NAME: str
“CurrentPositionLift” the name of this attribute
- data_type: st.zigbee.data_types.Uint16
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint16 object of this attribute with any additional features provided for the attribute
This is also usable with the CurrentPositionLift(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint16- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint16
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.WindowCovering.CurrentPositionTilt
- ID: number
0x0004 the ID of this attribute
- NAME: str
“CurrentPositionTilt” the name of this attribute
- data_type: st.zigbee.data_types.Uint16
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint16 object of this attribute with any additional features provided for the attribute
This is also usable with the CurrentPositionTilt(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint16- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint16
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.WindowCovering.NumberOfActuationsLift
- ID: number
0x0005 the ID of this attribute
- NAME: str
“NumberOfActuationsLift” the name of this attribute
- data_type: st.zigbee.data_types.Uint16
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint16 object of this attribute with any additional features provided for the attribute
This is also usable with the NumberOfActuationsLift(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint16- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint16
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.WindowCovering.NumberOfActuationsTilt
- ID: number
0x0006 the ID of this attribute
- NAME: str
“NumberOfActuationsTilt” the name of this attribute
- data_type: st.zigbee.data_types.Uint16
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint16 object of this attribute with any additional features provided for the attribute
This is also usable with the NumberOfActuationsTilt(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint16- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint16
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.WindowCovering.ConfigOrStatus
- ID: number
0x0007 the ID of this attribute
- NAME: str
“ConfigOrStatus” the name of this attribute
- data_type: st.zigbee.data_types.Bitmap8
the data type of this attribute
- OPERATIONAL: number
1
- ONLINE: number
2
- OPEN_AND_UP_COMMANDS_REVERSED: number
4
- LIFT_CLOSED_LOOP: number
8
- TILT_CLOSED_LOOP: number
16
- LIFT_ENCODER_CONTROLLED: number
32
- TILT_ENCODER_CONTROLLED: number
64
- is_operational_set()
- Returns
True if the value of OPERATIONAL is non-zero
- Return type
boolean
- set_operational()
Set the value of the bit in the OPERATIONAL field to 1
- unset_operational()
Set the value of the bits in the OPERATIONAL field to 0
- is_online_set()
- Returns
True if the value of ONLINE is non-zero
- Return type
boolean
- set_online()
Set the value of the bit in the ONLINE field to 1
- unset_online()
Set the value of the bits in the ONLINE field to 0
- is_open_and_up_commands_reversed_set()
- Returns
True if the value of OPEN_AND_UP_COMMANDS_REVERSED is non-zero
- Return type
boolean
- set_open_and_up_commands_reversed()
Set the value of the bit in the OPEN_AND_UP_COMMANDS_REVERSED field to 1
- unset_open_and_up_commands_reversed()
Set the value of the bits in the OPEN_AND_UP_COMMANDS_REVERSED field to 0
- is_lift_closed_loop_set()
- Returns
True if the value of LIFT_CLOSED_LOOP is non-zero
- Return type
boolean
- set_lift_closed_loop()
Set the value of the bit in the LIFT_CLOSED_LOOP field to 1
- unset_lift_closed_loop()
Set the value of the bits in the LIFT_CLOSED_LOOP field to 0
- is_tilt_closed_loop_set()
- Returns
True if the value of TILT_CLOSED_LOOP is non-zero
- Return type
boolean
- set_tilt_closed_loop()
Set the value of the bit in the TILT_CLOSED_LOOP field to 1
- unset_tilt_closed_loop()
Set the value of the bits in the TILT_CLOSED_LOOP field to 0
- is_lift_encoder_controlled_set()
- Returns
True if the value of LIFT_ENCODER_CONTROLLED is non-zero
- Return type
boolean
- set_lift_encoder_controlled()
Set the value of the bit in the LIFT_ENCODER_CONTROLLED field to 1
- unset_lift_encoder_controlled()
Set the value of the bits in the LIFT_ENCODER_CONTROLLED field to 0
- is_tilt_encoder_controlled_set()
- Returns
True if the value of TILT_ENCODER_CONTROLLED is non-zero
- Return type
boolean
- set_tilt_encoder_controlled()
Set the value of the bit in the TILT_ENCODER_CONTROLLED field to 1
- unset_tilt_encoder_controlled()
Set the value of the bits in the TILT_ENCODER_CONTROLLED field to 0
- augment_type(base_type_obj)
Add additional functionality to the base type object
- Parameters
base_type_obj (
st.zigbee.data_types.Bitmap8
) – the base data type object to add functionality to
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Bitmap8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Bitmap8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Bitmap8 object of this attribute with any additional features provided for the attribute
This is also usable with the ConfigOrStatus(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Bitmap8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attribute
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.WindowCovering.CurrentPositionLiftPercentage
- ID: number
0x0008 the ID of this attribute
- NAME: str
“CurrentPositionLiftPercentage” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the CurrentPositionLiftPercentage(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.WindowCovering.CurrentPositionTiltPercentage
- ID: number
0x0009 the ID of this attribute
- NAME: str
“CurrentPositionTiltPercentage” the name of this attribute
- data_type: st.zigbee.data_types.Uint8
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint8 object of this attribute with any additional features provided for the attribute
This is also usable with the CurrentPositionTiltPercentage(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint8
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.WindowCovering.InstalledOpenLimitLift
- ID: number
0x0010 the ID of this attribute
- NAME: str
“InstalledOpenLimitLift” the name of this attribute
- data_type: st.zigbee.data_types.Uint16
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint16 object of this attribute with any additional features provided for the attribute
This is also usable with the InstalledOpenLimitLift(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint16- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint16
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.WindowCovering.InstalledClosedLimitLift
- ID: number
0x0011 the ID of this attribute
- NAME: str
“InstalledClosedLimitLift” the name of this attribute
- data_type: st.zigbee.data_types.Uint16
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint16 object of this attribute with any additional features provided for the attribute
This is also usable with the InstalledClosedLimitLift(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint16- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint16
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.WindowCovering.InstalledOpenLimitTilt
- ID: number
0x0012 the ID of this attribute
- NAME: str
“InstalledOpenLimitTilt” the name of this attribute
- data_type: st.zigbee.data_types.Uint16
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint16 object of this attribute with any additional features provided for the attribute
This is also usable with the InstalledOpenLimitTilt(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint16- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint16
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.WindowCovering.InstalledClosedLimitTilt
- ID: number
0x0013 the ID of this attribute
- NAME: str
“InstalledClosedLimitTilt” the name of this attribute
- data_type: st.zigbee.data_types.Uint16
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint16 object of this attribute with any additional features provided for the attribute
This is also usable with the InstalledClosedLimitTilt(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint16- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint16
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.WindowCovering.VelocityLift
- ID: number
0x0014 the ID of this attribute
- NAME: str
“VelocityLift” the name of this attribute
- data_type: st.zigbee.data_types.Uint16
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint16 object of this attribute with any additional features provided for the attribute
This is also usable with the VelocityLift(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint16- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint16
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint16
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.WindowCovering.AccelerationTimeLift
- ID: number
0x0015 the ID of this attribute
- NAME: str
“AccelerationTimeLift” the name of this attribute
- data_type: st.zigbee.data_types.Uint16
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint16 object of this attribute with any additional features provided for the attribute
This is also usable with the AccelerationTimeLift(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint16- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint16
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint16
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.WindowCovering.DecelerationTimeLift
- ID: number
0x0016 the ID of this attribute
- NAME: str
“DecelerationTimeLift” the name of this attribute
- data_type: st.zigbee.data_types.Uint16
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Uint16
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Uint16 object of this attribute with any additional features provided for the attribute
This is also usable with the DecelerationTimeLift(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Uint16- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.Uint16
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- write(device, value)
Write a value to this attribute on a device
- Parameters
device (
st.zigbee.Device
) –value (
st.zigbee.data_types.Uint16
) – the value to write
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.WindowCovering.Mode
- ID: number
0x0017 the ID of this attribute
- NAME: str
“Mode” the name of this attribute
- data_type: st.zigbee.data_types.Bitmap8
the data type of this attribute
- MOTOR_DIRECTION_REVERSED: number
1
- CALIBRATION_MODE: number
2
- MAINTENANCE_MODE: number
4
- LED_FEEDBACK: number
8
- is_motor_direction_reversed_set()
- Returns
True if the value of MOTOR_DIRECTION_REVERSED is non-zero
- Return type
boolean
- set_motor_direction_reversed()
Set the value of the bit in the MOTOR_DIRECTION_REVERSED field to 1
- unset_motor_direction_reversed()
Set the value of the bits in the MOTOR_DIRECTION_REVERSED field to 0
- is_calibration_mode_set()
- Returns
True if the value of CALIBRATION_MODE is non-zero
- Return type
boolean
- set_calibration_mode()
Set the value of the bit in the CALIBRATION_MODE field to 1
- unset_calibration_mode()
Set the value of the bits in the CALIBRATION_MODE field to 0
- is_maintenance_mode_set()
- Returns
True if the value of MAINTENANCE_MODE is non-zero
- Return type
boolean
- set_maintenance_mode()
Set the value of the bit in the MAINTENANCE_MODE field to 1
- unset_maintenance_mode()
Set the value of the bits in the MAINTENANCE_MODE field to 0
- is_led_feedback_set()
- Returns
True if the value of LED_FEEDBACK is non-zero
- Return type
boolean
- set_led_feedback()
Set the value of the bit in the LED_FEEDBACK field to 1
- unset_led_feedback()
Set the value of the bits in the LED_FEEDBACK field to 0
- augment_type(base_type_obj)
Add additional functionality to the base type object
- Parameters
base_type_obj (
st.zigbee.data_types.Bitmap8
) – the base data type object to add functionality to
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Bitmap8
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.Bitmap8
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a Bitmap8 object of this attribute with any additional features provided for the attribute
This is also usable with the Mode(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a Bitmap8- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attribute
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.WindowCovering.IntermediateSetpointsLift
- ID: number
0x0018 the ID of this attribute
- NAME: str
“IntermediateSetpointsLift” the name of this attribute
- data_type: st.zigbee.data_types.OctetString
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.OctetString
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.OctetString
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a OctetString object of this attribute with any additional features provided for the attribute
This is also usable with the IntermediateSetpointsLift(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a OctetString- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.OctetString
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.WindowCovering.IntermediateSetpointsTilt
- ID: number
0x0019 the ID of this attribute
- NAME: str
“IntermediateSetpointsTilt” the name of this attribute
- data_type: st.zigbee.data_types.OctetString
the data type of this attribute
- augment_type(base_type_obj)
- Parameters
base_type_obj (
any
) –
- build_test_attr_report(device, data)
Build a Rx Zigbee message as if a device reported this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.OctetString
) – the attribute value
- Returns
containing an AttributeReport body
- Return type
- build_test_read_attr_response(device, data)
Build a Rx Zigbee message as if a device sent a read response for this attribute
- Parameters
device (
st.zigbee.Device
) –data (
st.zigbee.data_types.OctetString
) – the attribute value
- Returns
containing an ReadAttributeResponse body
- Return type
- new_value(...)
Create a OctetString object of this attribute with any additional features provided for the attribute
This is also usable with the IntermediateSetpointsTilt(…) syntax
- Parameters
vararg (
vararg
) – the values needed to construct a OctetString- Return type
- read(device)
Construct a st.zigbee.ZigbeeMessageTx to read this attribute from a device
- Parameters
device (
st.zigbee.Device
) –- Returns
containing a ReadAttribute body
- Return type
- configure_reporting(device, min_rep_int, max_rep_int, rep_change)
Construct a st.zigbee.ZigbeeMessageTx to configure this attribute for reporting on a device
- Parameters
device (
st.zigbee.Device
) –min_rep_int (
number or st.zigbee.data_types.Uint16
) – the minimum interval allowed between reports of this attributemax_rep_int (
number or st.zigbee.data_types.Uint16
) – the maximum interval allowed between reports of this attributerep_change (
st.zigbee.data_types.OctetString
) – The amount of change of the attribute to trigger a report
- Returns
containing a ConfigureReporting body
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
WindowCovering Commands
- class st.zigbee.zcl.clusters.WindowCovering.UpOrOpen
- ID: number
0x00 the ID of this command
- NAME: str
“UpOrOpen” the name of this command
- get_fields()
- static deserialize(buf)
Deserialize this command
- Parameters
buf (
buf
) – the bytes of the command body- Return type
UpOrOpen
- set_field_names()
- static build_test_rx(device)
Build a version of this message as if it came from the device
- Parameters
device (
st.zigbee.Device
) – the device to build the message from- Returns
The full Zigbee message containing this command body
- Return type
- init(self, device)
Initialize the UpOrOpen command
- Parameters
self (
UpOrOpen
) – the template class for this commanddevice (
st.zigbee.Device
) – the device to build this message to
- Returns
the full command addressed to the device
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.WindowCovering.DownOrClose
- ID: number
0x01 the ID of this command
- NAME: str
“DownOrClose” the name of this command
- get_fields()
- static deserialize(buf)
Deserialize this command
- Parameters
buf (
buf
) – the bytes of the command body- Return type
DownOrClose
- set_field_names()
- static build_test_rx(device)
Build a version of this message as if it came from the device
- Parameters
device (
st.zigbee.Device
) – the device to build the message from- Returns
The full Zigbee message containing this command body
- Return type
- init(self, device)
Initialize the DownOrClose command
- Parameters
self (
DownOrClose
) – the template class for this commanddevice (
st.zigbee.Device
) – the device to build this message to
- Returns
the full command addressed to the device
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.WindowCovering.Stop
- ID: number
0x02 the ID of this command
- NAME: str
“Stop” the name of this command
- get_fields()
- static deserialize(buf)
Deserialize this command
- Parameters
buf (
buf
) – the bytes of the command body- Return type
Stop
- set_field_names()
- static build_test_rx(device)
Build a version of this message as if it came from the device
- Parameters
device (
st.zigbee.Device
) – the device to build the message from- Returns
The full Zigbee message containing this command body
- Return type
- init(self, device)
Initialize the Stop command
- Parameters
self (
Stop
) – the template class for this commanddevice (
st.zigbee.Device
) – the device to build this message to
- Returns
the full command addressed to the device
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.WindowCovering.GoToLiftValue
- ID: number
0x04 the ID of this command
- NAME: str
“GoToLiftValue” the name of this command
- lift_value: st.zigbee.data_types.Uint16
- get_fields()
- static deserialize(buf)
Deserialize this command
- Parameters
buf (
buf
) – the bytes of the command body- Return type
GoToLiftValue
- set_field_names()
- static build_test_rx(device, lift_value)
Build a version of this message as if it came from the device
- Parameters
device (
st.zigbee.Device
) – the device to build the message fromlift_value (
st.zigbee.data_types.Uint16
) –
- Returns
The full Zigbee message containing this command body
- Return type
- init(self, device, lift_value)
Initialize the GoToLiftValue command
- Parameters
self (
GoToLiftValue
) – the template class for this commanddevice (
st.zigbee.Device
) – the device to build this message tolift_value (
st.zigbee.data_types.Uint16
) –
- Returns
the full command addressed to the device
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.WindowCovering.GoToLiftPercentage
- ID: number
0x05 the ID of this command
- NAME: str
“GoToLiftPercentage” the name of this command
- percentage_lift_value: st.zigbee.data_types.Uint8
- get_fields()
- static deserialize(buf)
Deserialize this command
- Parameters
buf (
buf
) – the bytes of the command body- Return type
GoToLiftPercentage
- set_field_names()
- static build_test_rx(device, percentage_lift_value)
Build a version of this message as if it came from the device
- Parameters
device (
st.zigbee.Device
) – the device to build the message frompercentage_lift_value (
st.zigbee.data_types.Uint8
) –
- Returns
The full Zigbee message containing this command body
- Return type
- init(self, device, percentage_lift_value)
Initialize the GoToLiftPercentage command
- Parameters
self (
GoToLiftPercentage
) – the template class for this commanddevice (
st.zigbee.Device
) – the device to build this message topercentage_lift_value (
st.zigbee.data_types.Uint8
) –
- Returns
the full command addressed to the device
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.WindowCovering.GoToTiltValue
- ID: number
0x07 the ID of this command
- NAME: str
“GoToTiltValue” the name of this command
- tilt_value: st.zigbee.data_types.Uint16
- get_fields()
- static deserialize(buf)
Deserialize this command
- Parameters
buf (
buf
) – the bytes of the command body- Return type
GoToTiltValue
- set_field_names()
- static build_test_rx(device, tilt_value)
Build a version of this message as if it came from the device
- Parameters
device (
st.zigbee.Device
) – the device to build the message fromtilt_value (
st.zigbee.data_types.Uint16
) –
- Returns
The full Zigbee message containing this command body
- Return type
- init(self, device, tilt_value)
Initialize the GoToTiltValue command
- Parameters
self (
GoToTiltValue
) – the template class for this commanddevice (
st.zigbee.Device
) – the device to build this message totilt_value (
st.zigbee.data_types.Uint16
) –
- Returns
the full command addressed to the device
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –
- class st.zigbee.zcl.clusters.WindowCovering.GoToTiltPercentage
- ID: number
0x08 the ID of this command
- NAME: str
“GoToTiltPercentage” the name of this command
- percentage_tilt_value: st.zigbee.data_types.Uint8
- get_fields()
- static deserialize(buf)
Deserialize this command
- Parameters
buf (
buf
) – the bytes of the command body- Return type
GoToTiltPercentage
- set_field_names()
- static build_test_rx(device, percentage_tilt_value)
Build a version of this message as if it came from the device
- Parameters
device (
st.zigbee.Device
) – the device to build the message frompercentage_tilt_value (
st.zigbee.data_types.Uint8
) –
- Returns
The full Zigbee message containing this command body
- Return type
- init(self, device, percentage_tilt_value)
Initialize the GoToTiltPercentage command
- Parameters
self (
GoToTiltPercentage
) – the template class for this commanddevice (
st.zigbee.Device
) – the device to build this message topercentage_tilt_value (
st.zigbee.data_types.Uint8
) –
- Returns
the full command addressed to the device
- Return type
- set_parent_cluster(cluster)
- Parameters
cluster (
any
) –